$JLOHQW $3ULPDU\)UHTXHQF\6WDQGDUG7HOHFRPPXQLFDWLRQV2SWLRQV7HOHFRPPXQLFDWLRQV2SWLRQV6XSSOHPHQWDO0DQXDO
Contentsvi
viiPrefaceThis manual provides operating, programming, and assembly-level service information for the HP 5071A Primary Frequency Standard Telecommunic
PrefaceviiiInstruments Covered by This manualThis manual applies to any HP 5071A Primary Frequency Standard that is equipped with one or more of the
1Operating and Programming
Operating and ProgrammingIntroduction1-2IntroductionThis section describes the additions, changes, and deletions to theinformation that appears in the
Operating and ProgrammingGetting Started1-3Getting StartedThis section describes the additions, changes, and deletions to theinformation that appears
Operating and ProgrammingGetting Started1-4 5071A Rear Panel Connections(See Table 1-1 in this chapter for connector descriptions)NOTEThe illustration
Operating and ProgrammingGetting Started1-5120 Vac7TELECOMOPTIONS:48Volt1.544 Mb/s2.048 Mb/s048 104105220270221271222272Operating Voltage Range:40 to
Operating and ProgrammingGetting Started1-6Table 1-1 Rear-Panel Telecommunications Options ConnectionsItemNumberFunctionConnectorTypeSignal Character
Operating and ProgrammingUsing the 5071A1-7Using the 5071AThis section describes the additions, changes, and deletions to theinformation that appear
Operating and ProgrammingIn Case of Difficulty1-8In Case of DifficultyThis section describes the additions, changes, and deletions to theinformation t
Operating and Programming5071A Command References1-9 5071A Command ReferencesThis section describes the additions, changes, and deletions to theinform
Operating and ProgrammingSpecifications1-10SpecificationsRefer to chapter 3 of this manual for telecommunications optionsspecification changes.
Operating and ProgrammingInstallation1-11InstallationThis section describes the additions, changes, and deletions to theinformation that appears in ch
Operating and ProgrammingInstallation1-12Preparing the RP 5071-A For External-Dc OperationDelete the existing procedure and use the following procedur
2Assembly-Level Service
Assembly-Level ServicePerformance Tests2-2Performance TestsThis section describes the additions, changes, and deletions to theinformation that appears
Assembly-Level ServiceService2-3ServiceThis section describes the additions, changes, and deletions to theinformation that appears in chapter 2 of the
Assembly-Level ServiceService2-4Figure 2-1. Instrument Top ViewThe “Batteries (Hidden behind battery door)”callout is changed to:48 Vdc Input Termina
Assembly-Level ServiceService2-5Warm-up and Fatal Error Diagnostic Tree(Diagnostic Subsection 3)1.3.1.1 Operating Error-Code InterpretationOn page 2-2
Agilent 5071A Primary Frequency StandardTelecommunications Options Supplemental ManualThis manual describes the Telecommunications options for the Agi
Assembly-Level ServiceService2-61.4.4.2.1 A1C4 Voltage Test ProcedureThe QUESTION, is changed to:Is the voltage between 45 and 51 Vdc?1.4.4.3 LF1/T1 T
Assembly-Level ServiceService2-72.1.1.1.2 A11/A11 Cable TestStep 2 text is changed to:Verify that the voltage present is between 45 and 51 Vdc with no
Assembly-Level ServiceService2-8Assembly/Module Diagnostic Trees(Diagnostic Section 3)A8 Diagnostic Tree (A/M Subsection 3)3.3.3 1 PPS Outputs TestSte
Assembly-Level ServiceService2-9A9 Diagnostic Tree (A/M Subsection 4)3.4.5.0 A9 Mon Signal TestThis procedure is deleted.3.4.6.0 A9 J4 80-MHz Signal
Assembly-Level ServiceTheory of Operation2-10Theory of OperationThis section describes the additions, changes, and deletions to theinformation that ap
Assembly-Level ServiceTheory of Operation2-11Input/Output BlockThe first sentence of the second paragraph is changed to:The block also receives a fron
Assembly-Level ServiceTheory of Operation2-12Figure 3-2. 5071 A Overall Block Diagram (Continued)The A8 1 PPS Assembly has the following input/outpu
Assembly-Level ServiceTheory of Operation2-13Table 3-2. Reference Oscillator/RF-Chain Block InterconnectionsThe following interconnection information
Assembly-Level ServiceTheory of Operation2-14Power Supply BlockThe first sentence of the first paragraph at the top of page 3-22 ischanged:The Power-S
Assembly-Level ServiceTheory of Operation2-15Table 3-6. Power Supply Block InterconnectionsThe following signal name information in table 3-6 on page
Agilent Technologies, Inc. 8.CD.NL.A.03.11.97.R1.J.CW2FSanta Clara Site5301 Stevens Creek BoulevardSanta Clara, California 95052-8059Copyright Agilen
Assembly-Level ServiceTheory of Operation2-16A11 Power Steering Logic AssemblyThe paragraph that describes the power-steering logic circuit on page 3-
Assembly-Level ServiceTheory of Operation2-17The slot/module interconnect diagram on page 3-28 is changed:The J3 Low Current Steering Logic connector
Assembly-Level ServiceTheory of Operation2-18Figure 3-5. A1 Power-Supply Block DiagramThe Power Supply block diagram on page 3-30 is changed:• The E
Assembly-Level ServiceReplaceable Parts2-19Replaceable PartsThis section describes the additions, changes, and deletions to theinformation that appear
Assembly-Level ServiceReplaceable Parts2-20
Assembly-Level Service2-21BACKDATINGThis section describes the additions, changes, and deletions to theinformation that appears in chapter 7 of the 5
Assembly-Level ServiceBACKDATING2-22
3Specifications
SpecificationsSupplemental Characteristics3-2Supplemental CharacteristicsThis section describes the additions, changes, and deletions to theinformatio
SpecificationsSupplemental Characteristics3-3WeightThe following are changed:Net weight: 28 kg (61 lb.).Shipping weight: 38 kg (83 lb.).Accessories Fu
MANUAL UPDATING CHANGES CHANGE DATE: December 12, 2001MANUAL UPDATING COVERAGEThis supplement adapts your manual toSerial Numbers prefixed through:US
SpecificationsAvailable Accessories and Options3-4Available Accessories and OptionsThis section describes the additions, changes, and deletions to the
Printed in U.S.AData subject to changeRev 12/2000Service and SupportContacting Agilent Technologies:For more information about Agilent test and measur
Continued from front matter. . .8.CD.NL.A.03.11.97.R1.J.CW2BWarranty (contd)Agilent does not warrant that the operation of Agilent products will be un
DECLARATION OF CONFORMITYAccording to ISO/IEC Guide 22 and CEN/CENELEC EN 45014Manufacturer’s Name:Agilent Technologies, Inc.Manufacturer’s AddressSan
Manual Part Number 05071-90042 Printed in U.S.A., DECEMBER 2000
LIST OF EFFECTIVE PAGESSERIAL PREFIX, SERIAL #OR DATE CODEPAGES(05071-90042, December 2000)# All Serials ... 3-3.All Serials ...
iiiPrefaceHow to Use This Manual vInstrument Identification vInstruments Covered by This Manual viManual Organization viHow to Order Manuals vi1 Opera
ContentsivInstallation 1-10Preparation for Use 1-10Power Requirements 1-10Bench Operation 1-10Operating the HP 5071A From External Dc Power 1-10Pr
Contentsv3 SpecificationsSupplemental Characteristics 3-2Time Standard 3-2Clock 1PPS Outputs 3-2Clock Synchronization 3-2Internal Standby Ba
Comments to this Manuals