Agilent Technologies InfiniiVision 7000B Series Service Manual

Browse online or download Service Manual for Fridge-freezers Agilent Technologies InfiniiVision 7000B Series. Agilent Technologies InfiniiVision 7000B Series Technical data User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Evaluation Guide

 Agilent InfiniiVision 7000B Series OscilloscopesEvaluation Guide

Page 2

Demo Board Getting Started Guide10 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide Front Panel Overview1 Run Control - When the osci

Page 3

Demo Board Getting Started GuideAgilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 11 3 Horizontal Control:a Turn the large knob in the

Page 4 - Demo Equipment and Set Up

Demo Board Getting Started Guide12 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 4 Vertical Controls:a Turn the large yellow knob

Page 5

Demo Board Getting Started GuideAgilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 13 6 To o l s :a Press the [Clear Display] key to cl

Page 6 - In This Guide

14Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 1Capturing and Viewing Complex Signals with MegaZoom TechnologyViewing deep memo

Page 7

Capturing and Viewing Complex Signals with MegaZoom Technology 1Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 15 7 Set the channel

Page 8

1 Capturing and Viewing Complex Signals with MegaZoom Technology16 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide Note that, in add

Page 9

Capturing and Viewing Complex Signals with MegaZoom Technology 1Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 17 22 Adjust the hor

Page 10 - Front Panel Overview

18Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 2Using Auto Scale, Cursors, Measurements, and Waveform MathIn this lab, we use s

Page 11

Using Auto Scale, Cursors, Measurements, and Waveform Math 2Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 19 When [Auto Scale] is

Page 12

Notices© Agilent Technologies, Inc. 2008-2009No part of this manual may be reproduced in any form or by any means (including electronic stor-age and r

Page 13

2 Using Auto Scale, Cursors, Measurements, and Waveform Math20 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 14 When the popup men

Page 14

Using Auto Scale, Cursors, Measurements, and Waveform Math 2Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 21 With “tracking” curso

Page 15

2 Using Auto Scale, Cursors, Measurements, and Waveform Math22 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 28 Press [Math].29 Pr

Page 16

Using Auto Scale, Cursors, Measurements, and Waveform Math 2Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 23 The value of the “X1”

Page 17

24Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 3Discovering an Infrequent Glitch with Fast Waveform Update RatesCapturing infre

Page 18 - Using Auto Scale, Cursors

Discovering an Infrequent Glitch with Fast Waveform Update Rates 3Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 25 With the infini

Page 19

3 Discovering an Infrequent Glitch with Fast Waveform Update Rates26 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 13 Next, press

Page 20

27Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 4Using Pass/Fail Mask Testing to Discover a Signal ViolationWith mask testing yo

Page 21

4 Using Pass/Fail Mask Testing to Discover a Signal Violation28 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 13 Press Create Mask

Page 22

Using Pass/Fail Mask Testing to Discover a Signal Violation 4Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 29 In addition to stopp

Page 23

Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 3 Agilent InfiniiVision 7000B Series OscilloscopesAgilent’s InfiniiVision 7000 Serie

Page 24

30Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 5Viewing Multiple Signals in an MCU-based Design with an MSOIn mixed analog and

Page 25

Viewing Multiple Signals in an MCU-based Design with an MSO 5Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 31 The channel 2 signal

Page 26

5 Viewing Multiple Signals in an MCU-based Design with an MSO32 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide The oscilloscope sho

Page 27 - Discover a Signal Violation

Viewing Multiple Signals in an MCU-based Design with an MSO 5Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 33 Although the oscillo

Page 28

34Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 6Verifying I2C Serial Bus CommunicationMany of today’s embedded designs include

Page 29

Verifying I2C Serial Bus Communication 6Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 35 Notice that the oscilloscope may trigger

Page 30 - MCU-based Design with an MSO

6 Verifying I2C Serial Bus Communication36 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide You should now be able to view the time-a

Page 31

Verifying I2C Serial Bus Communication 6Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 37 The oscilloscope should now be triggering

Page 32

6 Verifying I2C Serial Bus Communication38 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 18 To scroll through a stored list of I2C

Page 33

39Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 7Verifying SPI Serial Bus CommunicationAnother common serial bus protocol used i

Page 34

4 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 2. FAST — 100,000 Waveforms Per Second.Have you turned your oscilloscope’s deep me

Page 35 - Verifying I

7 Verifying SPI Serial Bus Communication40 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 7 Press [Serial]; then, select the SPI de

Page 36 - 6 Verifying I

Verifying SPI Serial Bus Communication 7Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 41 The oscilloscope should now be triggering

Page 37

7 Verifying SPI Serial Bus Communication42 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 19 Rotate the selection knob to scroll th

Page 38

43Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 8Verifying RS-232/UART Serial Bus CommunicationThe RS-232 and UART serial buses

Page 39 - Communication

8 Verifying RS-232/UART Serial Bus Communication44 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 9 To configure the bus for odd pa

Page 40

Verifying RS-232/UART Serial Bus Communication 8Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 45 With default labels turned on, we

Page 41

8 Verifying RS-232/UART Serial Bus Communication46 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide You should now see the encoded me

Page 42

Verifying RS-232/UART Serial Bus Communication 8Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 47 21 To scroll through a stored lis

Page 43

48Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 9Verifying CAN Serial Bus CommunicationThe Controller Area Network (CAN) bus is

Page 44

Verifying CAN Serial Bus Communication 9Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 49 9 Press [Digital] to turn on digital chan

Page 45

Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 5 connecting a USB cable between it and the Agilent InfiniiVison 7000B Series oscill

Page 46

9 Verifying CAN Serial Bus Communication50 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide The oscilloscope should now be triggering

Page 47

Verifying CAN Serial Bus Communication 9Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 51 verify that these signals have correlated

Page 48 - Verifying CAN Serial Bus

9 Verifying CAN Serial Bus Communication52 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 24 Press [Mode/Coupling]; then, press Mod

Page 49

Verifying CAN Serial Bus Communication 9Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 53 30 To scroll through a stored list of CAN

Page 50

54Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 10Verifying LIN Serial Bus CommunicationThe LIN serial bus is another protocol t

Page 51

Verifying LIN Serial Bus Communication 10Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 55 The oscilloscope should now be decoding

Page 52

10 Verifying LIN Serial Bus Communication56 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide Notice the first byte in the serial deco

Page 53

Verifying LIN Serial Bus Communication 10Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 57 19 To scroll through a stored list of LI

Page 54 - Verifying LIN Serial Bus

58Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 11Verifying I2S Serial Bus CommunicationThe Integrated Interchip sound (I2S) bus

Page 55

Verifying I2S Serial Bus Communication 11Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 59 You should now see I2S decoding based on

Page 56

6 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide In This GuideIf you are experiencing the InfiniiVision 7000 Series oscilloscope fo

Page 57

11 Verifying I2S Serial Bus Communication60 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide (default setting). To analyze left and r

Page 58

61Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 12Using Segmented Memory Acquisition to Capture More DataSegmented Memory acquis

Page 59 - S Serial Bus Communication 11

12 Using Segmented Memory Acquisition to Capture More Data62 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide It may appear that the

Page 60 - 11 Verifying I

Using Segmented Memory Acquisition to Capture More Data 12Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 63 The oscilloscope should

Page 61 - Using Segmented Memory

12 Using Segmented Memory Acquisition to Capture More Data64 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide Part B: Using Segmented

Page 62

Using Segmented Memory Acquisition to Capture More Data 12Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 65 The oscilloscope should

Page 63

12 Using Segmented Memory Acquisition to Capture More Data66 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 19 Press [Serial].20 Pr

Page 64 - Bus Signals

67Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 13Using Serial Search and NavigationSearching through a deep memory acquisition

Page 65

13 Using Serial Search and Navigation68 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 11 Set the timebase to 50 ms/div in order to

Page 66

Using Serial Search and Navigation 13Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 69 Let’s now set up the oscilloscope to automat

Page 67

7Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide Demo Board Getting Started GuideIf you are not familiar with the Agilent InfiniiV

Page 68

13 Using Serial Search and Navigation70 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide In addition to navigating to specific frames

Page 69

71Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide Appendix AUsing Trigger Holdoff to Synchronize Acquisitions/Display on Complex S

Page 70

A Using Trigger Holdoff to Synchronize Acquisitions/Display on Complex Signals72 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide Not

Page 71 - Appendix A

Using Trigger Holdoff to Synchronize Acquisitions/Display on Complex Signals AAgilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 73 We

Page 74

 Agilent Technologies, Inc. 2008-2009Printed in U.S.A.First edition, November 2009*N2918-97004*N2918-97004www.agilent.comAgilent InfiniiVision 700

Page 75

Demo Board Getting Started Guide8 Agilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide Menu line forsoftkey controlof menus selectedon th

Page 76 - *N2918-97004*

Demo Board Getting Started GuideAgilent InfiniiVision 7000B Series Oscilloscopes Evaluation Guide 9 Run control,defaultsetup, andautoscaleSelection kn