Agilent Technologies54600-Series OscilloscopesData SheetMultiple configurations to meet your needsIf you work with both analog and digital components,
10MegaZoom deep memory helpsyou determine how your signalsare impacting each other. Withshallow memory scopes, you haveto choose whether you look at a
11Quickly pan and zoom for analysis with MegaZoom’s instantresponse and optimum resolution.Autoscale lets you quickly display any active signals,autom
12Probes To get the most out of your scope,you need the right probes andaccessories for your particularapplication. That's why AgilentTechnologie
13Performance CharacteristicsAcquisition: Analog ChannelsMax Sample Rate 54621A/D, 54622A/D, 54624A: 200 MSa/s54641A/D, 54642A/D: 2 GSa/sec interleave
14Performance Characteristics (continued)Vertical System: Analog Channels (continued)Range1,254621A/D, 54622A/D, 54624A: 1 mV/div to 5 V/div54641A/D,
15Performance Characteristics (continued)Vertical System: Digital Channels (54621D, 54622D, 54641D, and 54642D only)Number of Channels 16 Digital – la
16Performance Characteristics (continued)Horizontal (continued)Digital Delta-t Accuracy 54621A/D, 54622A/D, 54624A:(non-Vernier settings) Same Channe
17Performance Characteristics (continued)Trigger System (continued)I2C Trigger on I2C (Inter-IC bus) serial protocol at a start/stop condition or user
18Performance Characteristics (continued)Display SystemDisplay 7-inch raster monochrome CRTThroughput of Analog Channels 25 million vectors/sec per ch
19Performance Characteristics (continued)StorageSave/Recall (non-volatile) 54621A/D, 54622A/D, 54624A: 3 setups and traces can be saved and recalled i
2Selection GuideFigure 1. 2 + 16-channel mixed signal oscilloscope (MSO) family shown with 2- and 4-channel models.Selection Guide Model Bandwidth Max
20Performance Characteristics (continued)Power RequirementsLine Voltage Range 54621A/D, 54622A/D, 54624A: 100 - 240 VAC ±10%, CAT II, automatic select
21Ordering InformationDescription54621A 2-channel 60 MHz Oscilloscope54621D 2+16 channel 60 MHz Mixed Signal Oscilloscope54622A 2-channel 100 MHz Osci
22Available Options DescriptionOption 003 Shielding Option for use in severe environments or with sensitive devices under test – shields both ways (in
23Ordering Information (continued)Fine Pitch Probing Description10072A Fine-pitch probe kit10075A 0.5 mm, IC clip kit E2613B 0.5mm, Wedge probe adapte
Call the measurement experts at Agilent TechnologiesWhether your work is mostly digital, mostly analog, or somewhere in the middle, our measurement sp
3Figure 2. 2 + 16-channel mixed signal oscilloscope (MSO) allows you to view analog and digital content on one instrument.Mixed-signal scopes (models
4Affordable and ResponsiveMegaZoom deep memoryWith 4 MB to 8 MB of MegaZoomdeep memory, 54600-Seriesscopes give you deep-memorycapture without the slu
5Affordable and Responsive (continued)Revolutionary high-definition dis-play helps you see detailsCombine MegaZoom deep memorywith a patented high-def
6Deep memory transfer over the busTransfer all of your data over thebus, even when using deep memory. Typical transfer time is <70 seconds for 2 MB
7N2758A CAN Trigger Module• Trigger on CAN 2.0A/B messageframes with user specified IDsand/or data• Trigger on Error frames• Differential CAN• Acknowl
8TriggeringFlexible TriggeringWith mixed analog and digitaldesigns, sometimes it is hard totrace an anomaly back to its rootcause unless you can trigg
9Triggering (continued)I2C and SPI TriggeringDon’t spend your time sortingthrough communication frames tofind the one of interest. LetAgilent set up a