Agilent 16451B DIELECTRIC MATERIAL TEST FIXTURE Operation Manual
Manual Change
Agilent Part No. N/A
June 2008
Change 1
Following note is added on the following designated locations.
NOTE
Be careful not to contaminate or not to make a scratch on the surface of the electrode. A scratch or contamination of
the electrode’s surface sometimes prevents the measured capacitance from falling within the limits shown in
“Electrode Adjustment” (Page 3-36). If it happens, replace the scratched/contaminated electrode or contact your
nearest Agilent Technologies Sales and Service Office. As long as the measured capacitance falls within the limits, the
electrode doesn’t need to be replaced or repaired.
Locations:
1. Page 3-29
2. Page 3-37
3. Page 3-41
4. Page 3-44
5. Page 4-8
Change 2
Correct Table 1-2 (Page1-4) as follows.
Compatible Instrument Model Measurement
Frequency Range
4192A LF Impedance Analyzer 5 Hz - 13 MHz
4194A Impedance/Gain-Phase Analyzer 100 Hz - 40 MHz
*1
4263B LCR Meter 100Hz - 100kHz
4268A 120Hz/1kHz Capacitance Meter 120Hz/1kHz
4278A 1 kHz/1 MHz Capacitance Meter 1 kHz/1 MHz
4279A 1 MHz C-V Meter 1 MHz
4284A Precision LCR Meter 20 Hz - 1 MHz
4285A Precision LCR Meter 75kHz - 30MHz
4288A 1 kHz/1 MHz Capacitance Meter 1 kHz/1 MHz
4294A Precision Impedance Analyzer 40Hz - 110MHz
*2
E4980A Precision LCR Meter 20 Hz – 20 MHz
Change 3
Correct the note for table 1-2 in page 1-4.
*1: The upper frequency of the 4194A is 40 MHz but it is limited to 30 MHz when used with the 16451B.
*2: The upper frequency of the 4294A is 110 MHz but it is limited to 30 MHz when used with the 16451B.
Page view 0
1 2 3 4 5 6 ... 148 149

Summary of Contents

Page 1 - Manual Change

○C Copyright 2008 Agilent Technologies Agilent 16451B DIELECTRIC MATERIAL TEST FIXTURE Operation Manual Manual Change Agilent Part No. N/A

Page 13

MANUAL CHANGESAgilent 16451BDIELECTRIC TEST FIXTUREOperation and Service ManualMANUAL IDENTIFICATIONModel Number: 16451BDate Printed: Oct. 2000Part N

Page 24

Page 4-5, Table 4-3. Replaceable Parts List (3 of 5)ReferenceDesignator Part Number Qty Description1 16451-20022 1 Base

Page 56

REGIONAL SALES AND SUPPORT OFFICES For more information about Agilent Technologies test and measurement products, applications, services, and for a cu

Page 62

○C Copyright 2008 Agilent Technologies Change 4 Correct Table 1-3 (Page1-5) as follows. Instrument Model Number Correction Function 1m C

Page 73

○C Copyright 2008 Agilent Technologies Change 6 Replace the contents of page 2-4 by the following, Dissipation Factor Accuracy (Δ tan

Page 84

○C Copyright 2008 Agilent Technologies Change 7 Correct the sentence at “16451B Overview” in page 3-1. The 16451B is a test fixture for

Page 95

○C Copyright 2008 Agilent Technologies Agilent 16451B DIELECTRIC MATERIAL TEST FIXTURE Operation Manual マニュアル チェンジ Agilent Part No. N/A J

Page 106

○C Copyright 2008 Agilent Technologies 変更 3 1-4 ページの表 1-2 の脚注を下記に変更してください。 *1: 16451B を使用する際の 4194A の測定周波数の上限は、30 MHz となります。 *2: 16451B

Page 117

○C Copyright 2008 Agilent Technologies 6-2: 2-4 ページ 測定確度の項に下記を追加してください。 電極 A と電極 B だけに対応する確度を表す。 被測定材料の両面が理想的に平行・平坦で滑らかであることを前提とする。

Page 128

○C Copyright 2008 Agilent Technologies

Page 139

○C Copyright 2008 Agilent Technologies 4294A の設定条件 1. 信号レベル: 500 mV 2. BW: 5 3. ケーブル長: 1m 4. 補正: オープン/ショート/ロード 変更 7 3 章 16451B の

Comments to this Manuals

No comments