Agilent N1913A and N1914A
EPM Series Power Meters
Consistent results and greater capability
Data Sheet
Do more with new-generation EPM power meters
Get up to four channels
[1]
to speed and simplify RF average power measurements
Measure faster with improved measurement speed of 400 readings/sec with the Agilent
E-Series sensors
View test results more easily with the industrys first color LCD readout in an average
power meter
Go beyond GPIB with USB and LAN/LXI-C interfaces
Automate frequency/power sweep measurements with the optional external trigger in/out
feature
Confirm battery power with a single-button push
[2]
and get extra operating time with
the optional spare battery
Easily replace existing 436A. 437B and 438A meters with optional 43x code
compatibility
[3]
Enhance manufacturing test by connecting a large external monitor with the unique VGA
output option
[1] Additional two optional USB channels available (see Ordering Information, page 9)
[2] Only applicable for models with battery option (see Ordering Information, page 9)
[3] N1913A is backward compatible with the 436A and 437B, while N1914A is compatible with 438A
Essential specifications
Frequency range: 9 kHz to 110 GHz
Power range: 70 dBm to +44 dBm
(100 pW to 25 W, depending on the
attached power sensor)
Measurement speed: Up to 400
readings/sec with E-Series sensors
Absolute accuracy: ±0.02 dB
logarithmic, ±0.5% linear
Relative accuracy: ±0.04 dB
logarithmic, ±1% linear
As signals become more complex, it becomes
more difficult to make fast, accurate power
measurements. For years, youve depended
on Agilents EPM Series power meters. Today,
the Agilent N1913A and N1914A EPM power
meters are versatile, user-friendly
replacements for the E4418B/19B EPM
Series. Best of all, you get these extras for
about the same price as the EPM Series. Get
consistent results and greater capability
with the new EPM power meters.
Page view 0
1 2 3 4 5 6 ... 24 25

Summary of Contents

Page 1 - Agilent N1913A and N1914A

Agilent N1913A and N1914AEPM Series Power MetersConsistent results and greater capabilityData SheetDo more with new-generation EPM power meters Get u

Page 2 - Take a closer look

10E-Series power sensor specificationsThe E-Series of power sensors have their calibration factors stored in EEPROM and operate over a wide dynamic ra

Page 3

E-Series CW power sensor specificationsThe chart in Figure 1 shows the typicaluncertainty in making a relative powermeasurement, using the same power

Page 4 - Measurement speed

12E-Series E9300 average power sensor specificationsThe E-Series E9300 wide dynamic range, average power sensors are designed for use with the EPM fam

Page 5 - Settling time

Typical SWR, 10 MHz to 18 GHz (25 °C ±10 °C)for E9300H and E9301H sensors13E-Series E9300 average power sensor specificationsTypical SWR, 10 MHz to 18

Page 6 - Settling time (continued)

Typical E9300H/01H power linearity at 25 °C, after zero and calibration, withassociated measurement uncertaintyPower range26 to 20 dBm20 to 10 dBm

Page 7 - Power Meter Functions

15E-Series E9300 average power sensor specificationsEffects of change in temperature on linearityNote: If the temperature changes after calibration an

Page 8 - Environmental characteristics

16E-Series E9300 average power sensor specificationsSwitch point dataThe E9300 power sensors have two paths asshown in Table 7. The power meterautomat

Page 9 - Power meters

17E-Series E9300 average power sensor specificationsTable 12b: Calibration factor uncertainties (high power path)Frequency10 MHz to 30 MHz30 MHz to 50

Page 10

188480D Series diode and 8483A thermocouple power sensor specificationsCalibration factor uncertaintiesThese thermocouple and diode power sensors prov

Page 11 - Power linearity

198480D Series diode and 8483A thermocouple power sensor specificationsMaximum SWR and power linearityTable 14: 8480 Series maximum SWR and power line

Page 12

Take a closer lookN1914A front panelN1914A back panel2Rear-panel sensor and PowerRef connectors provide anoption to replace front-panelconnectorsDC re

Page 13

20N8480 Series thermocouple power sensor specificationsThe N8480 Series power sensors (excluding Option CFT) measure power levels from 35 dBm to +44

Page 14 - Power (dBm)

21N8480 Series thermocouple power sensor specificationsMaximum SWR and power linearity for standard N8480 Series power sensorsTable 16: N8480 Series m

Page 15

22N8480 Series thermocouple power sensor specificationsSwitch point dataSwitching point is applicable for standard N8480 Series power sensors only.The

Page 16 - Switch point data

23U2000 Series USB power sensor specificationsThe U2000 Series USB power sensors are true average, wide-dynamic-range RF/microwave power sensors, base

Page 17 - Calibration factor (CF) and

24U2000 Series USB power sensor specificationsMaximum SWRFor more detailed specifications,refer to theAgilent U2000 Series USB power sensorsdatasheet

Page 18

www.agilent.com/find/emailupdatesGet the latest information on theproducts and applications you select.www.agilent.com/find/agilentdirectQuickly choos

Page 19

N1913A/14A Series power meter: applications and compatible sensors for averagepower measurementsMetrologylabPulse/averagedRadar/navigationModulatedWir

Page 20

4Specifications describe the instruments warranted performance and applyafter a 30 minute warm-up. These specifications are valid over itsoperating/e

Page 21

51. Settling time: 0 to 99% settled readings over the GPIB2. When a power step crosses through the sensors auto-range switch point, add 25 ms. Refer

Page 22

N1913A/14A EPM Series power meters performance characteristicsSettling time (continued)Auto filter, 10 dB decreasing power step for normal and X2 mode

Page 23 - Power Accuracy

7N1913A/14A EPM Series power meters performance characteristicsRear panel connectorsRecorder outputs: Analog 0 to 1 Volt, 1 kW output impedance, BNC c

Page 24 - Maximum SWR

8N1913A/14A EPM Series power meters performance characteristicsOperating environmentTemperature: 0 °C to 55 °CMaximum Humidity: 95 % at 40 °C (non-con

Page 25 - Remove all doubt

9N1913A/14A EPM Series power meters ordering informationPower metersN1913A: Single-channel average power meterN1914A: Dual-channel average power meter