Agilent Technologies 8496G Service Manual

Browse online or download Service Manual for Multimeters Agilent Technologies 8496G. Agilent Technologies 8496G Service manual User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Attenuators

Agilent TechnologiesAgilent 8494/95/96G/H AttenuatorsOperating and Service Manual

Page 2

10 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 1 IntroductionProduct OverviewThe 8494G/H, 8495G/H, and 8496G/H are 50- ohm coaxia

Page 3 - WEEE Compliance

Introduction 1Agilent 8494/95/96G/H Attenuators Operating and Service Manual 11Table 1 on page 11, Table 2 on page 12, and Table 3 on page 12 show t

Page 4 - Regulatory Markings

12 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 1 IntroductionTable 2 8495G/H Attenuator Switching Order8494G/H Attenuator Section

Page 5 - Contacting Agilent

Introduction 1Agilent 8494/95/96G/H Attenuators Operating and Service Manual 13Each solenoid requires a drive of 20 V to 30 V with a switching curren

Page 6

14 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 1 IntroductionInstrument OptionsEach instrument is specified with an option number

Page 7 - Contents

Introduction 1Agilent 8494/95/96G/H Attenuators Operating and Service Manual 15SpecificationsFrequency Range and AttenuationTable 5 Frequency Range a

Page 8

16 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 1 IntroductionAttenuation Accuracy(±dB): (Referenced from 0 dB)Table 6 Attenuation

Page 9 - Introduction

Introduction 1Agilent 8494/95/96G/H Attenuators Operating and Service Manual 17Maximum SWRMaximum Residual AttenuationAttenuation Repeatability±0.03

Page 10 - Product Overview

18 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 1 IntroductionRF Power Handling Capability1 W average, 100 W peak with maximum pul

Page 11

Introduction 1Agilent 8494/95/96G/H Attenuators Operating and Service Manual 19Solenoid Cable ConnectorRefer also to Figure 3.Figure 3 Solenoid Cable

Page 12 - 1 Introduction

2 Agilent 8494/95/96G/H Attenuators Operating and Service ManualNotices© Agilent Technologies, Inc. 2011-2012No part of this manual may be reproduced

Page 13

20 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 1 IntroductionOperating Life 5 million cycles per section.Switching Speed Maximum

Page 14 - Instrument Options

21Agilent 8494/95/96G/H AttenuatorsOperating and Service ManualAgilent Technologies2Environmental Specifications & Physical DimensionsEnvironmenta

Page 15 - Specifications

22 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 2 Environmental Specifications & Physical DimensionsEnvironmental Specification

Page 16 - Attenuation Accuracy

Environmental Specifications & Physical Dimensions 2Agilent 8494/95/96G/H Attenuators Operating and Service Manual 23Physical DimensionsTable 12 s

Page 17 - Maximum Residual Attenuation

24 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 2 Environmental Specifications & Physical DimensionsFigure 4 Dimensions of Agil

Page 18 - Solenoid Drive

25Agilent 8494/95/96G/H AttenuatorsOperating and Service ManualAgilent Technologies3Operating GuidesInstallation 26Initial Inspection 26Mating Connect

Page 19 - Solenoid Cable Connector

26 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 3Operating GuidesInstallationInitial Inspection1 Inspect the shipping container for

Page 20 - Switching Speed

Operating Guides 3Agilent 8494/95/96G/H Attenuators Operating and Service Manual 27Mating ConnectorsMating RF connectors used with the Option 001 must

Page 21 - Physical Dimensions

28 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 3Operating GuidesOperating InstructionsEither RF connector may be used as the input

Page 22 - Environmental Specifications

Operating Guides 3Agilent 8494/95/96G/H Attenuators Operating and Service Manual 29Figure 5 Operator’s Check SetupProcedure1 Connect equipment as show

Page 23

Agilent 8494/95/96G/H Attenuators Operating and Service Manual 3CertificationAgilent Technologies certifies that this product met its published specif

Page 24

30 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 3Operating GuidesTable 1 3 Attenuator and SWR SettingsSWR Meter Range(dB)Attenuation

Page 25 - Operating Guides

Operating Guides 3Agilent 8494/95/96G/H Attenuators Operating and Service Manual 31Performance TestsThe Agilent 8494/95/96G/H Attenuators can be teste

Page 26 - Installation

32 Agilent 8494/95/96G/H Attenuators Operating and Service Manual 3Operating GuidesThis page is intentionally left blank.

Page 27 - Installation Instructions

4 Agilent 8494/95/96G/H Attenuators Operating and Service ManualRegulatory MarkingsThe CE mark is a registered trademark of the European Community. I

Page 28 - Operating Instructions

Agilent 8494/95/96G/H Attenuators Operating and Service Manual 5Contacting Agilent For more information, please contact your nearest Agilent office.Or

Page 29 - Procedure

6 Agilent 8494/95/96G/H Attenuators Operating and Service ManualThis page is intentionally left blank.

Page 30 - 3Operating Guides

Agilent 8494/95/96G/H Attenuators Operating and Service Manual 7Contents1 Introduction 9Product Overview 10Instrument Options 14Specifications 15Freq

Page 31 - Service Instructions

8 Agilent 8494/95/96G/H Attenuators Operating and Service ManualThis page is intentionally left blank.

Page 32

9Agilent 8494/95/96G/H AttenuatorsOperating and Service ManualAgilent Technologies1IntroductionProduct Overview 10Instrument Options 14Specifications

Comments to this Manuals

No comments