Data Sheet
PDFINFO H 5 6 0 1 - 0 1
16-Channel Low-Offset Relay
Multiplexer
Agilent E1345A
1-Slot, B-size, register based
General purpose, low-offset relay multiplexer
Low thermal offset reed relays, <4 µV
16-channel 3-wire or 8-channel 4-wire multiplexer
Shunt/series signal conditioning elements
Channel scanning with Agilent DMMs
Agilent E1345A
Description
The Agilent E1345A General-Purpose Reed Relay Multiplexer
is a B-size, 1-slot, register-based VXI module that
switches 16 channels of high, low, and guard each. The
multiplexer has low thermal offset performance. This module
consists of a B-size component card (labeled E1345-66201)
and a screw terminal block that plugs onto the component
card. The E1345A is functionally similar to the E1347A.
The E1345A multiplexer is arranged into two banks of eight
switches, each having its own common high, low, and guard
screw terminals accessible on the terminal block. Tree-
switched common high, low, and guard screw terminals and
analog bus connections provide access to all 16 channels. The
module may be programmed as either a single 1x16 three-wire
multiplexer, two independent 1x8 three-wire multiplexers (for
four-wire ), or a 1x8 six-wire multiplexer.
Configuration
One analog bus cable is shipped with each module, making it
easy to connect common outputs together for slot-adjacent
modules. If you are using a B-size mainframe, Agilent E1300B
or E1301B, use the analog bus cable shipped with the E1326B
DMM to connect it to the multiplexer(s).
C-size Adapter
For installing the E1345A in a C-size mainframe, the E1403C
active adapter is recommended.
Refer to the Agilent Technologies Website for instrument
driver availability and downloading instructions, as well as for
recent product updates, if applicable.
Agilent Technologies
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - Multiplexer

Data SheetPDFINFO H 5 6 0 1 - 0 116-Channel Low-Offset RelayMultiplexerAgilent E1345A• 1-Slot, B-size, register based • General purpose, low-offset re

Page 2 - General Specifications

PDFINFO H 5 6 0 1 - 0 22Product SpecificationsInputDC:Maximum voltage (any terminal to any other terminal orchassis): 120 VdcAC rms:Maximum voltage (a

Page 3 - Ordering Information

PDFINFO H 5 6 0 1 - 0 33Analog bus cables for MUX-to-MUX and MUX-to-multimeterconnectionsAnalog bus cables for MUX-to-MUX and MUX-to-multimeterconnect

Page 4 - PDFINFO H 5 6 0 1 - 0 4

PDFINFO H 5 6 0 1 - 0 44Signal Conditioning Components/Current Shunt

Page 5

Related Literature2000 Test System and VXI Catalog CD-ROM,Agilent Pub. No. 5980-0308E (detailed specifications for VXI products)2000 Test System and V

Comments to this Manuals

No comments