Agilent Technologies 81680A User's Guide

Browse online or download User's Guide for Networking Agilent Technologies 81680A. Agilent Technologies 81680A User`s guide User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - User’s Guide

Agilent 83433ALightwave TransmitterUser’s Guide

Page 2

1-2Getting StartedSetting Up the Agilent 83433ASetting Up the Agilent 83433AThe instructions in this chapter show you how to install your lightwave tr

Page 3 - General Safety Considerations

1-3Getting StartedSetting Up the Agilent 83433AStep 1. Inspect the ShipmentNOTEThe Agilent 83433A is supplied with an optical jumper cable. To avoid c

Page 4

1-4Getting StartedSetting Up the Agilent 83433AIf anything is missing or defective, or if the lightwave transmitter does not pass the verification tes

Page 5

1-5Getting StartedSetting Up the Agilent 83433AStep 2. Check the Fuse 1Locate the line-input connector on the instrument’s rear panel.2Disconnect the

Page 6

1-6Getting StartedSetting Up the Agilent 83433AStep 3. Connect the Line-Power CableCAUTIONAlways use the three-prong AC power cord supplied with this

Page 7 - Contents

1-7Getting StartedSetting Up the Agilent 83433A2Connect the line-power cord to the rear-panel connector of the instrument.3Connect the other end of th

Page 8

1-8Getting StartedSetting Up the Agilent 83433AStep 4. Turn on the Agilent 83433A• Press the front-panel LINE key. All front-panel LED’s will light mo

Page 9

1-9Getting StartedSetting Up the Agilent 83433AStep 5. Avoid costly repairsCAUTIONFiber-optic connectors are easily damaged when connected to dirty or

Page 10 - Setting Up the Agilent 83433A

1-10Getting StartedSetting Up the Agilent 83433AStep 6. Learn more about our productsTo learn more about this or any Agilent Technologies product, vis

Page 11 - Step 1. Inspect the Shipment

2Front-Panel Features 2-2Rear-Panel Features 2-4Using a Laser Source 2-5Performing a Quick Confidence Check 2-6Connecting the Agilent 83433A to a Bit-

Page 12 - Getting Started

ii© Copyright Agilent Technologies 2000All Rights Reserved. Repro-duction, adaptation, or trans-lation without prior written permission is prohibited,

Page 13 - Step 2. Check the Fuse

2-2Using the Agilent 83433AFront-Panel FeaturesFront-Panel FeaturesLASER ENABLE This key disables the Internal Class IIIB laser when in the OFF posi

Page 14 - 230 VAC: 50 WATTS MAX

2-3Using the Agilent 83433AFront-Panel FeaturesWAVELENGTH ADJUST ENABLE Toggles between preset laser wavelength and wavelength adjust mode. (Light tu

Page 15

2-4Using the Agilent 83433ARear-Panel FeaturesRear-Panel Features

Page 16

2-5Using the Agilent 83433AUsing a Laser SourceUsing a Laser SourceThe Agilent 83433A contains an IEC LASER Class 3B according to IEC 60825. The total

Page 17 - Step 5. Avoid costly repairs

2-6Using the Agilent 83433APerforming a Quick Confidence CheckPerforming a Quick Confidence CheckThis procedure verifies the basic functionality of th

Page 18

2-7Using the Agilent 83433APerforming a Quick Confidence Check5Connect the data output of the pattern generator to the DATA INPUT of the 83433A.6Use t

Page 19 - Using the Agilent 83433A

2-8Using the Agilent 83433APerforming a Quick Confidence CheckIf the verification check failsIf the lightwave transmitter does not pass the verificati

Page 20 - Front-Panel Features

2-9Using the Agilent 83433AConnecting the Agilent 83433A to a Bit-Error-Ratio Test SetConnecting the Agilent 83433A to a Bit-Error-Ratio Test SetThe f

Page 21

2-10Using the Agilent 83433AConnecting the Agilent 83433A to a Bit-Error-Ratio Test Set Figure 2-2. Connecting the Agilent 83433A to a bit-error-ratio

Page 22 - Rear-Panel Features

2-11Using the Agilent 83433AConnecting the Agilent 83433A to an OscilloscopeConnecting the Agilent 83433A to an OscilloscopeThe following procedure de

Page 23 - Using a Laser Source

iiiGeneral Safety ConsiderationsGeneral Safety ConsiderationsThis product has been designed and tested in accordance with IEC Publica-tion 61010-1, Sa

Page 25

3Options 3-2Replacement Parts 3-3Front-Panel Fiber-Optic Adapters 3-4Power Cords 3-5Cleaning Connections for Accurate Measurements 3-6Returning the In

Page 26

3-2ReferenceOptionsOptionsAccessories suppliedThe Agilent 83433A lightwave transmitter is shipped with: • FC/PC connector adapter on the optical outpu

Page 27 - Bit-Error-Ratio Test Set

3-3ReferenceReplacement PartsReplacement PartsTable 3-2. Replaceable PartsDescription Agilent Part NmmberAPC 3.5 F-to-F (connector saver) 5061-5311APC

Page 28

3-4ReferenceFront-Panel Fiber-Optic AdaptersFront-Panel Fiber-Optic AdaptersFront PanelFiber-Optic AdapterDescription Agilent Part NumberDiamond HMS-1

Page 29 - Oscilloscope

3-5ReferencePower CordsPower CordsPlug Type Cable Part No. Plug DescriptionLength (in/cm)Color Country250V 8120-13518120-1703Straight *BS1363A90°90/22

Page 30

3-6ReferenceCleaning Connections for Accurate MeasurementsCleaning Connections for Accurate Measurements Today, advances in measurement capabilities m

Page 31 - Reference

3-7ReferenceCleaning Connections for Accurate MeasurementsFigure 3-1. Basic components of a connector.Over the last few years, the FC/PC style connect

Page 32 - Accessories supplied

3-8ReferenceCleaning Connections for Accurate MeasurementsThe HMS-10 encases the fiber within a soft nickel silver (Cu/Ni/Zn) center which is surround

Page 33 - Replacement Parts

3-9ReferenceCleaning Connections for Accurate MeasurementsInspecting ConnectorsBecause fiber-optic connectors are susceptible to damage that is not im

Page 34

ivGeneral Safety ConsiderationsCAUTIONThis product is designed for use in Installation Category II and Pollution Degree 2 per IEC 61010-1 and 664 resp

Page 35 - Power Cords

3-10ReferenceCleaning Connections for Accurate MeasurementsFigure 3-4. Clean, problem-free fiber end and ferrule.Figure 3-5. Dirty fiber end and ferru

Page 36 - Choosing the Right Connector

3-11ReferenceCleaning Connections for Accurate Measurementsnectors, using small glass spheres. When used with contacting connectors, these glass balls

Page 37

3-12ReferenceCleaning Connections for Accurate Measurementsduce a good return-loss measurement. The quality of the polish establishes the difference b

Page 38

3-13ReferenceCleaning Connections for Accurate MeasurementsCAUTIONAgilent Technologies strongly recommends that index matching compounds not be applie

Page 39 - Inspecting Connectors

3-14ReferenceCleaning Connections for Accurate MeasurementsTo clean a non-lensed connector CAUTIONDo not use any type of foam swab to clean optical fi

Page 40

3-15ReferenceCleaning Connections for Accurate MeasurementsDo not scrub during this initial cleaning because grit can be caught in the swab and become

Page 41

3-16ReferenceCleaning Connections for Accurate Measurements3Dry the inside of the adapter with a clean, dry, foam swab. 4Blow through the adapter usin

Page 42 - Cleaning Connectors

3-17ReferenceReturning the Instrument for ServiceReturning the Instrument for Service The instructions in this section show you how to properly return

Page 43

3-18ReferenceReturning the Instrument for ServicePreparing the instrument for shipping 1Write a complete description of the failure and attach it to t

Page 44

3-19ReferenceReturning the Instrument for Servicerugated cardboard carton of 159 kg (350 lb) test strength. • The carton must be large enough to allow

Page 45

vGeneral Safety ConsiderationsLaser classificationThe Agilent 83433A is classified as an IEC LASER Class 3B according to IEC 825-1:1999-11, and an FDA

Page 46

Agilent Technologies Service OfficesBefore returning an instrument for service, call the Agilent Technologies Instrument Support Center at (800) 403-0

Page 47

4Agilent 83433A Specifications and Characteristics 4-3Regulatory Information 4-6Specifications and Regulatory Information

Page 48

4-2Specifications and Regulatory InformationSpecifications and Regulatory InformationSpecifications and Regulatory InformationThis chapter lists speci

Page 49

4-3Specifications and Regulatory InformationAgilent 83433A Specifications and CharacteristicsAgilent 83433A Specifications and Characteristics OPERATI

Page 50

4-4Specifications and Regulatory InformationAgilent 83433A Specifications and CharacteristicsModulated Optical OutputModulator insertion lossOptical p

Page 51 - Information

4-5Specifications and Regulatory InformationAgilent 83433A Specifications and CharacteristicsEMI Radiated and conducted emissions are in compliance wi

Page 52

4-6Specifications and Regulatory InformationRegulatory InformationRegulatory Information• Laser Classification: This product contains an IEC LASER Cla

Page 53 - Characteristics

4-7Specifications and Regulatory InformationRegulatory InformationDeclaration of Conformity

Page 55

IndexIndex-1Aaccessories, 3-2adapters, 2-3fiber optic, 3-4adjustingwavelength, 2-2Agilent offices, 3-20BBERTconnecting to, 2-9bit-error-ratio test set

Page 56 - Regulatory Information

viThe Agilent 83433A—At a GlanceThe Agilent 83433A—At a GlanceThe Agilent 83433A lightwave transmitter is based on a lithium niobate modu-lator driven

Page 57 - Declaration of Conformity

Index-2IndexMmaintenance contract, 2-8measurementaccuracy, ivNnoise declaration, 4-6Ooptical out connector, 2-3oscilloscopeconnecting to, 2-11Ppackagi

Page 58

ContentsContents-1The Agilent 83433A—At a Glance vi1 Getting Started2 Using the Agilent 83433AFront-Panel Features 2-2Rear-Panel Features 2-4Using a L

Page 60

1Step 1. Inspect the Shipment 1-3Step 2. Check the Fuse 1-5Step 3. Connect the Line-Power Cable 1-6Step 4. Turn on the Agilent 83433A 1-8Step 5. Avoid

Comments to this Manuals

No comments