Agilent Technologies E6392B User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
8560 EC Series Spectrum Analyzer
high sensitivity, wide dynamic
range
phase noise: <–113 dBc/Hz at
10 kHz, 1 GHz
displayed average noise level:
–151 dBm
1 Hz resolution bandwidth (RBW)
OBW/ACP measurement functions
time-gated function
Agilent 8560 EC Series spectrum
analyzers offer a solution for adjacent
channel power (ACP) testing of
bursted carrier signals using digital
modulation, such as time-division
multiple access (TDMA) and time
division complex (TDD).
The 8560 EC Series allows measure-
ments from 0.10 to 99.99% occupied
bandwidth.
For more information,
please go to our Web site at:
www.agilent.com/find/8560.
ESA-E Series Portable Spectrum
Analyzers
third order intercept: +12.5 dB
ACPR 1st offset dynamic range:
–67 dBc
displayed average noise level:
–166 dBm
EVM modulation analysis
2G/3G multi-format RF power
measurements
wide range of detectors including
RMS and average detectors
flexible platform
frequency coverage to 26.5 GHz
seven measurement personalities
8590 Series code compatibility
The Agilent ESA-E Series spectrum
analyzers with the modulation
analysis measurement personality
provides the flexibility of general
purpose spectrum analysis combined
with the numerical and visual tools
that help to quickly identify and
quantify impairments to digitally
modulated signals for all major
cellular standards.
For more information,
please go to our Web site at:
www.agilent.com/find/esa.
N4256A Amplifier Distortion Test Set
extend measurement dynamic
range for IMD and other amplifier
distortion measurements
500 MHz to 4 GHz frequency range
designed to extend dynamic
range performance of Agilent
PSA and ESA series spectrum
analyzers
reduces signal generator
distortion products
The Agilent N4256A amplifier distor-
tion test set improves dynamic range
of spectrum analyzer based distortion
measurements that are made on
today’s ultra-linear 3G power
amplifiers. The N4256A utilizes a
feed-forward cancellation technique to
minimize signal generator distortion
products and to improve spectrum
analyzer dynamic range for IMD and
ACPR measurements. Measurement
dynamic range improvements as great
as 25 dB are typical. The N4256A
allows you to make distortion
measurements where the distortion
products are no longer buried in the
spectrum analyzer’s noise floor,
which results in improved
measurement uncertainty.
For more information,
please go to our Web site at:
www.agilent.com/find/componenttest.
10
Spectrum Analyzers Distortion Test
R & D
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 23 24