Agilent Technologies 85309B IF Specifications

Browse online or download Specifications for Television antennas Agilent Technologies 85309B IF. Agilent Technologies 85309B IF Specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Analyzers

1Agilent PNA-X Series Microwave Network AnalyzersReach for unrivaled excellence

Page 2 - Reach for unrivaled

10Pulsed-RF measurement challenges • Pulse generators and modulators required for pulsed-RF measurements add complexity in test setups• For narrow

Page 3 - Multiple

11PNA-X’s narrowband detection method used for narrow pulse widths (< 267 ns) employs special hardware and patented software-gating techniques to i

Page 4 - Case Studies

12Innovative ApplicationsFast and accurate noise figure measurements(Options 028, 029)Noise figure measurement challenges with traditional, Y-factor a

Page 5 - CASE STUDY 4

13Noise-parameter measurements in minutes rather than daysNoise figure measurement methodsY-FACTOR: The most prevalent method for measuring noise figur

Page 6

14Innovative ApplicationsFast and accurate noise figure measurements(Option 028, 029) continuedPNA-X’s unique source-corrected noise figure solution•

Page 7

15Tips from the experts• Noise figure measurements are best done in a screen room to eliminate spurious interference from mobile phones, wireless LAN

Page 8 - Architecture

Innovative ApplicationsFast and accurate gain compression versus frequency measure-ments of amplifiers and converters(Option 086)Gain compression mea

Page 9 - Test port 2

Tips from the expertsPin Freq. Gain Compression Pin Freq. Gain Compression Available compression methods• Use the safe mode in SMART Sweep to increme

Page 10 - (Options 008, 021, 022, 025)

Innovative ApplicationsFast two-tone intermodulation distortion (IMD) measurements with simple setup(Option 087)IMD measurement challenges • Two

Page 11 - Tips from the experts

Tips from the expertsSwept IMD sweep types• Calibrate at all measurement frequencies or at center frequencies only, trading off productivity and acc

Page 12 - Applications

2Industry’s Most Advanced RF Test Solution Reach for unrivaled excellenceChoose the leader in network analysis The PNA-X Series of microwave network

Page 13

DUT Referencemixer Calibrationmixer/filterInnovative ApplicationsAccurate characterization of mixers and converters(Options 082, 083, 084)Mixer and

Page 14 - Fast and accurate

With two internal signal sources, the PNA-X provides fast measurements of both fixed and swept IF responses.Time-domain gating can remove ripple by re

Page 15

22Innovative ApplicationsControl relative magnitude and phase between two sources for active output-load control(Option 088) Amplifier load-pull measur

Page 16

23Innovative ApplicationsSimplified test of I/Q converters and modu-lators, and differential mixers (Option 089) I/Q and differential converter measur

Page 17

Innovative ApplicationsTesting differential amplifiers under real operating conditions(Option 460) Differential amplifier measurement challenges •

Page 18 - Fast two-tone

2 1 4 3 Phase-offset sweeps change the phase-offset value as if it were added in the fixture, enabling input-matching circuit validation.In-fixture phas

Page 19

26Innovative ApplicationsPowerful, fast and accurate automatic fixture removal (AFR)(Option 007)Powerful AFR features can handle a variety of measurem

Page 20 - (Options 082, 083, 084)

27AFR accuracy is comparable to on-board TRL calibration, but much easier to accomplish. Measurement exampleIn the plots below, the green trace is a

Page 21

Innovative ApplicationsExtending the PNA-X to millimeter-wave frequenciesPNA-X’s unique hardware architecture provides: • Two- and four-port sol

Page 22

Tips from the expertsMillimeter-wave applications with the PNA-XIntegrated pulse measurements The PNA-X’s internal pulse modulators create pulsed-R

Page 23

3 Multiple measurements with a single instrumentReplace racks and stacks With its highly integrated and versatile hardware and re-configurable mea

Page 24 - (Option 460)

Innovative ApplicationsNonlinear waveform and X-parameter characterization(Options 510, 514, 518, and 520) High-power design challenges• Active de

Page 25

Agilent’s award-winning NVNA goes beyond S-parameters to:• Efficiently and accurately analyze and design active devices and systems under real-world o

Page 26 - Measurement Challenge:

GatingIsolation housingIsolation housingSimplified transceiverLNAGatingControllerRF cableRF cableRF cableCustomerfurnishedantennaPATRInnovative Applica

Page 27 - Measurement example

PSG or MXGsignal source85309BLO/IFdistributionunit85320Breference mixer85320Atest mixerSourceantennaOptionalamplifierTrigger in/out10 MHzN5264A Opt.

Page 28 - PNA-X to

34Tips from the expertsGPSreceiver10 MHz inGPSreceiver10 MHz inAgilent N5181A Agilent N5264AHow do I get a common 10 MHz reference signal to my sourc

Page 29 - Millimeter-wave

35N5249A N5241A N5242AN5244AN5245AN5247AFrequency range10 MHz to 8.5 GHz10 MHz to 13.5 GHz 10 MHz to 26.5 GHzN5244A 10 MHz to 43.5 GHzN5245A 10 MHz to

Page 30

36PNA-X Network AnalyzersPNA-X Configuration Information Description Additional informationTest setOption 200 2-ports, single sourceOption 224 2-port

Page 31

37PNA-X Network AnalyzersPNA-X Configuration Information Description Additional informationPulse, antenna, mm-waveOption 008 Pulsed-RF measurements R

Page 32 - RF subsystem

www.agilent.com/find/pnamyAgilentmyAgilent www.agilent.com/find/myagilentA personalized view into the information most relevant to you.www.lxistandard

Page 33 - PNA-X measurement receiver?

4Bottom Line Results – PNA-X Case StudiesChallenges This customer manufacturers over 4600 RF components, with typically 1000 devices in the manufac

Page 34

5Challenges The manufacturer was developing a new broadband wireless network system and needed a faster test system. Its existing test system consist

Page 35 - Outstanding Performance

6Intuitive, Speed-driven FeaturesFlexible user interface: hard keys, soft keys, pull-down menus, and touch screenUp to 10 markers per traceState-of

Page 36 - Available options

7Hardware for Exceptional FlexibilitySecond GPIB interface for controlling signal sources, power meters or other instrumentsPulse I/O connector f

Page 37 - Available options, continued

8C R3 Test port 1 Test port 3R1 A Rear panel Source 1 OUT 1 OUT 2 Pulsemodulator Pulsemodulator Source 2 OUT 1 OUT 2 +28 V Signalcombiner + – J9 J10

Page 38 - (BP-01-15-14)

9Test port 4 R4 D Rear panel 1 2 3 4 Test port 2 R2 B Noise receiver 8.5/ 13.5/26.543.5/50 GHz To receivers LO J2 J1 J4 J3 3 6 45Pulse generators Sw

Comments to this Manuals