Agilent TechnologiesAgilent 86100A/B/C Infiniium DCA SeriesFirmware Release Notes
1086100A/B/CFirmware Release NotesA.06.00 Release Notes, December 15, 2005 (Differences from Release A.04.20)New Feature List• Added Enhanced Impedan
1186100A/B/CFirmware Release Notes86100C/86100B/86100A Firmware Release NotesA.05.00 Release Notes, February 16, 2005 (Differences from Release A.04.
1286100A/B/CFirmware Release Notesnormalization to enable faster edges.• Support for InfiniiMax II Series Probe• Enables calibration debugging for mod
1386100A/B/CFirmware Release Notesexit• Resolved STOP CHAN1 :TIME:RANG:MEAS:VTIM? causes abrupt application exit• Repaired MEASure:CGR:SOUR CGMemory c
1486100A/B/CFirmware Release NotesAdded additional settling time when setting the gain of the average power monitor.• Repaired Extinction ratio calibr
1586100A/B/CFirmware Release Notesthe noise floor of jitter measurements down to 200 fs in most circumstances.• Enhancements for 86100A/B/C Mainframes
1686100A/B/CFirmware Release NotesKnown Issues• 86119A (Optical Sampling Oscilloscope) is designed to work on software versions A.03.06 and A.03.05 on
1786100A/B/CFirmware Release Notesof timing jitter.• Separation and display of jitter components. Adds the pull down graphical display area.• Save and
1886100A/B/CFirmware Release Notes2 only or 4 only. Differential TDT data was not being saved and recalled properly.• Normalization cal data was being
1986100A/B/CFirmware Release NotesCHAN<N>.• Corrected debug assertion when the remote query :TRIGger:GATed? was sent.• Corrected problem with :H
© Copyright Agilent Technologies Company 2010All Rights Reserved. Reproduction, adaptation, or translation without prior written permission is prohib-
2086100A/B/CFirmware Release NotesDefects Fixed• Modified the RZ algorithm to take care of unsymmetrical edges• Corrected a problem with mask file nam
2186100A/B/CFirmware Release Notes86100A-Only Firmware Release NotesA.03.01 Release Notes, February 15, 2002 (Differences from Release A.02.20)New Fe
2286100A/B/CFirmware Release Noteschanging modes• Measurement limits do not work when restored from saved setups• Mask test align failure does not cau
2386100A/B/CFirmware Release Notesinstrument to crash while in eye mode.• The remote command mask load (MTES:LOAD) does not work in "C:\User File
2486100A/B/CFirmware Release NotesIn firmware versions previous to A.02.10, 5% of the [Ymax,Ymin] is used, assuming that the "crossing" posi
2586100A/B/CFirmware Release NotesDefects Fixed• Fixed a defect that was causing the trace to jump to the top of the graticule when vertical offset wa
2686100A/B/CFirmware Release NotesA.01.22 Release Notes, September 6, 2000 (Differences from Release A.01.21)NOTE This firmware release is not suppor
2786100A/B/CFirmware Release Notesdisabling it after it has been dismissed.• If a vertical calibration fails and the module is removed before dismissi
2886100A/B/CFirmware Release Notes
386100A/B/CFirmware Release NotesContents86100C-Only Firmware Release Notes 4A.09.01 Release Notes, July, 2010 (Differences from Release A.09.00) 4A.0
486100A/B/CFirmware Release Notes86100C-Only Firmware Release NotesA.09.01 Release Notes, July, 2010 (Differences from Release A.09.00)General Defect
586100A/B/CFirmware Release Notesembedded clocks from optical and electrical signals up to 16X Fibre Channel.• Support for 86105D Optical/Electrical M
686100A/B/CFirmware Release Notesconfigurations for a number of use cases to make the configuration as simple as possible.• Advanced Clock Data Recove
786100A/B/CFirmware Release NotesKnown Issues• 86119A (Optical Sampling Oscilloscope) is designed to work on software versions A.03.06 and A.03.05 onl
886100A/B/CFirmware Release NotesA.07.00 Release Notes, March 15, 2007 (Differences from Release A.06.01)New Features List• The following features ar
986100A/B/CFirmware Release NotesA.06.01 Release Notes, September 21, 2006 (Differences from Re-lease A.06.00)New Feature List• Added eye masks for 1