Agilent Technologies 6102A User's Guide

Browse online or download User's Guide for Power supply units Agilent Technologies 6102A. Agilent Technologies 6102A User`s guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Agilent Technologies
6000 Series Oscilloscopes
Data Sheet
The fastest way to debug your design
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - 6000 Series Oscilloscopes

Agilent Technologies6000 Series OscilloscopesData SheetThe fastest way to debug your design

Page 2

10Software applicationsFPGA dynamic probe (N5406A for Xilinx, N5434A for Altera)Give your MSO internal FPGA visibility. Agilent’s MSO FPGA dynamic pro

Page 3

11Software applications (continued)Random errors observed in CAN decode while triggering on data frame ID: 07FHEX.CRC errorCAN/LIN triggering and deco

Page 4

12Agilent 6000 Series oscilloscopes: The fastest way to debug your analog, digital and serial designs.MegaZoom III deep memory helps you determine ho

Page 5 - Other nice features

13Quickly pan and zoom for analysis with MegaZoom III’s instant response and optimum resolution.QuickMeas shows up to four automated measurements with

Page 6 - Why does deep memory matter?

14AccessoriesBattery power option (Option BAT – factory installed)Agilent 6000 Series oscilloscopes provide an optional internal rechargeable lithium

Page 7 - Time base setting

15Product selection guideFeatures that are available to all scopesChannel count; 2 or 4 (scope)Maximum sample rate: 4 GSa/sXGA display with 256 intens

Page 8 - Connectivity

16Performance characteristicsAcquisition: scope channels Sample rate MSO/DSO601xA/603xA: 2 GSa/sec each channel MSO/DSO605xA/610xA: 4 GSa/sec half

Page 9 - Probes and accessories

17Performance characteristics (continued)Vertical system: scope channelsScope channels MSO/DSO6xx2A: Ch 1 and 2 simultaneous acquisition MSO/DSO6x

Page 10 - Software applications

18Performance characteristics (continued)Vertical system: scope channels (continued)ESD tolerance ±2 kVNoise peak-to-peak MSO/DSO601xA: 3% full scal

Page 11 - (continued)

19Performance characteristics (continued)HorizontalRange MSO/DSO601xA: 5 nsec/div to 50 sec/div MSO/DSO603xA: 2 nsec/div to 50 sec/div MSO/DSO6

Page 12

2Identify your most elusive problems faster with:Fast update rate View infrequent anomalies that most scopes miss with an update rate 5000 times bette

Page 13

20Performance characteristics (continued)Trigger system (continued)Selections Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, FlexRay

Page 14 - Accessories

21Performance characteristics (continued)Trigger system (continued)Autoscale Finds and displays all active scope and logic (for MSO6000A series MSO)

Page 15 - Product selection guide

22Performance characteristics (continued)Display systemDisplay 6.3-inch (161 mm) diagonal color TFT LCDThroughput of scope channels Up to 100,000 wa

Page 16 - Performance characteristics

23Performance characteristics (continued)StorageSave/recall (non-volatile) 10 setups and traces can be saved and recalled internally. Optional sec

Page 17

24Performance characteristics (continued)General characteristics (continued)Trigger out When Triggers is selected (delay ~17 ns) 0 to 5 V into

Page 18

25 Maximum Scope DigitalModel Bandwidth sample rate Memory depth channels channelsDSO6012A 100 MHz 2 GSa/s 2 Mpts, 8 Mpts optional 2

Page 19

26Ordering information (continued)Product upgrades DSO601xA, MSO601xA DSO605xA, MSO605xA DSO603xA, MSO603xA DSO610xA, MSO610xA8 Mpts memory up

Page 20

27Related LiteraturePublication Title Publication Type Publication NumberAgilent Technologies Probes and Accessories Selection Guide 5989-6162ENAgil

Page 21

www.agilent.comFor more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complet

Page 22

3Serial: Hardware-accelerated decode and trigger for I2C, SPI, CAN, LIN and FlexRayDigital: 16 digital timing channels with mixed signal triggering An

Page 23

4If you haven’t purchased an Agilent oscilloscope lately, why should you consider one now?Model Bandwidth Maximum sample rate Memory depth Scope c

Page 24

5Other nice featuresHigh resolution mode Offers up to 12 bits of vertical resolution in real-time, single-shot mode. This is accomplished by serially

Page 25 - Ordering information

6Why does deep memory matter?See more timeThis is the most easily understood use of deep memory. The more samples that you acquire, the more time that

Page 26

7Why does a fast update rate matter?This is a question that we hear frequently. If the human eye has trouble discerning above 30-50 frames per second,

Page 27

8ConnectivityOur customers tell us that oscilloscope connectivity is an increasingly important feature of their test instruments. That’s why the 6000

Page 28 - Remove all doubt

9Probes and accessoriesAgilent offers a complete family of innovative passive and active probes for the 6000 Series scopes to get your job done easily