Page view 26
Test Details: Screen Shots and Discussion
Non-Pre-emphasized Level Test
Notes:
1. The nominal settings of Level 0, 1, 2, 3 are 400, 600, 800, and 1200 mVolts BUT we really
don’t care about the absolute level. What is important is the DIFFERENCE between
settings.
2. We measure the Non Transition voltage swing of two adjacent levels and compare.
October 29, 2012
Confidentiality Label
27
286mV
193mV
Level 0 to Level 1 Resultant = 20*Log (286/193)= 3.42 dB
Level setting 1
Level setting 0
Page view 26