192 Agilent U7232A DisplayPort Electrical Performance Compliance Test Application
21 Cable Eye Diagram Tests
Table 26 Cable Eye Vertices for TP3
Mask Test: Zero mask failures.
Test R ef er en ce s
See Test 3.1: Eye Diagram Testing, in the DisplayPort- Compliance Test
Specification Version 1.
Bit Rate
Mask Point Reduced (1.6 Gb/s) High (2.7 Gb/s)
1 0.375, 0.000 0.246, 0.000
2 0.500, 0.023 0.500, 0.075
3 0.625, 0.000 0.755, 0.000
4 0.500, -0.023 0.500, -0.075
Figure 69 The Cable Eye Mask at TP3