Agilent Technologies 42D Specifications Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 124
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
ii
The Oscilloscope At a Glance
Choose from a variety of oscilloscopes
all with 2 GSa/s sample rate and
2 MBytes of MegaZoom deep memory
per channel for capturing long,
non-repeating signals.
Agilent 54641A - 2-channel, 350-MHz
bandwidth
Agilent 54641D - 2-channel +16 logic
channels, 350-MHz bandwidth
Agilent 54642A - 2-channel, 500-MHz
bandwidth
Agilent 54642D - 2-channel +16 logic
channels, 500-MHz bandwidth
Display shows current input signals
All analog and digital (54641D/42D)
channels displayed in main and
delayed mode
Indicators for channel, time base,
digital (54641D/42D) channel activity,
trigger and acquisition status
Softkey labels
Measurement results
Digital channel controls select,
position, and label inputs (54641D/42D)
Turn channels on or off individually or
in groups of 8
Rearrange order of channels to group
related signals
Create and display labels to identify
channels
General controls measure, save and
restore results, and configure the
oscilloscope
Waveform math including FFT,
subtract, multiply, integrate, and
differentiate
Use Quick Meas to make automatic
measurements
Use cursors to make manual
measurements
Save or recall measurement
configurations or previous results
Autoscale performs simple
one-button setup of the oscilloscope
Horizontal Controls select sweep speed
and delay parameters
Sweep speeds from 1 ns/div to
50 s/div
Delay control moves waveform
display to point of interest
Delayed mode and delay allow
zooming in to show a portion of
waveform in detail (split screen)
Run control keys begin and end data
acquisition
Run/Stop starts and stops continuous
acquisitions
Single performs one acquisition
Infinite persistence accumulates and
displays the results of multiple
acquisitions
Trigger keys define what data the
oscilloscope will trigger on
Source key allows conventional
oscilloscope triggering
Modes include Edge, Pulse Width,
Pattern, CAN, Duration, I
2
C, LIN,
Sequence, SPI, TV, and USB
triggering
Softkeys extend the functionality of
command keys
Select measurement types, operating
modes, trigger specifications, label data,
and more
Digital channel inputs through a flexible
probing system (54641D/42D)
Sixteen channels through a dual
8-channel cable with micro-clips
Set logic levels as TTL, CMOS, ECL, or
to a user-definable voltage
Utilities
Dedicated parallel printer port,
controller operation, floppy disk
storage
Built in Quick Help system
Press and hold any key front-panel
key or softkey to get help in 11
languages.
service.book Page ii Wednesday, August 28, 2002 3:25 PM