Cellular and PCS frequency coverage in one box
Analog and TDMA test capabilities
Built-in average power meter with ±7.5% accuracy
Dedicated, one-button user interface keys
Firmware upgradeable (via PCMCIA to flash memory)
Automation software to increase measurement
repeatability and enhance technician efficiency
The Agilent Technologies 8935 Series E6381A
TDMA base station test set is a full-featured, one-
box test set designed to meet the needs of installa-
tion teams, service providers, and network equip-
ment manufacturers.
Building on the success of our previous genera-
tions of base station test equipment, the E6381A
heavily incorporates feedback from PCS and
Cellular users. For example, the E6381A utilizes a
large, bright, easy-to-read, electroluminescent dis-
play. A convenient connector section on the side
of the test set allows unobtrusive, out-of-the-way
hook up, as well as protects the connectors from
damage. A suitcase form factor provides better
portability.
The “rugged” design includes a reliable membrane
keypad, a gasketed display, and filtered
airflow to resist dirt and moisture. The unit’s
enclosure provides for stand up operation, and
helps protect itself from bumps and shocks.
The E6381A incorporates a user-friendly interface
with one-key measurement execution. This inter-
face, coupled with the test set’s fast measurement
speed and automated software for Ericsson,
Lucent, and Nortel base stations, results in less
off-line time and improved system performance.
Errors due to test variability are reduced, and
measurement data can be output to a printer or to
the PC memory card. Additionally, new features
and capabilities can be added to the E6381A with-
out returning the unit to a service center. The test
set’s firmware is user upgradeable via a PC card to
Flash Memory.
To complete the TDMA parametric test solution,
Agilent also offers a new TDMA technician training
program to provide install teams and service
providers with a comprehensive understanding of
base station test.
For more information about the E6381A, refer to
the 8935 series configuration guide on our Web
site at: www.agilent.com/find/assist
Agilent E6381A
8935 Series TDMA
Base Station Test Set
Specifications
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Base Station Test Set

• Cellular and PCS frequency coverage in one box• Analog and TDMA test capabilities• Built-in average power meter with ±7.5% accuracy• Dedicated, one-

Page 2 - Average Power Measurement

2Agilent 8935 Series E6381A TDMA Base Station Test SetSpecifications Specifications describe the instrument’s warranted performance and arevalid over

Page 3 - CDPD Analyzer

3OutputRF IN/OUT ConnectorLevel Range: –137 dBm to –40 dBm into 50 ΩLevel Accuracy: ±1.0 dB (level >–127 dBm); if CDPD analyzer is also connected a

Page 4 - RF Analyzer Measurements

4FM Accuracy (1 kHz rate):<10 kHz dev: ±3.5% of setting ±50 Hz,>10 kHz dev: ±3.5% of setting ±500 HzFM Distortion (THD + noise, in a 0.3 to 3 kH

Page 5 - Oscilloscope Specifications

5AM MeasurementFrequency Range: 10 MHz to 1 GHz (usable to 400 kHz), 1.7 GHzto 2.0 GHzDepth: 0 to 95%Input Level Range (levels in PEP):–6 dBm to +52 d

Page 6 - General Specifications

6DC Voltage MeasurementVoltage Range: 100 mV to 42 VAccuracy: ±1.0% of reading ±45 mVDC Offset: ±25 mVSupplemental CharacteristicsResolution: 1 mVDist

Page 7 - Remote Programming

7Leakage: At RF generator output levels <–40 dBm, typical radiated leakage is <10 µV induced in a resonant dipole antenna25 mm (1 inch) away fro

Page 8 - Ordering Number

Standard User Memory, RAMApproximately 928 Kbytes of RAM are available for nonvolatilesave/recall of settings. This will typically allow >500 sets