Agilent Technologies U3402A User Manual

Browse online or download User Manual for Multimeters Agilent Technologies U3402A. Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Agilent U3400 Series 4½ and 5½ Digit
Digital Multimeters
Basic + Good = Elegant Simplicity
Data Sheet
Features
Simply right for your basic needs,
without compromising quality
The U3400 Series digital multimeters (DMMs)
come with functions vital for your everyday
measurements: DC, AC and AC+ DC voltage
and current, 2- and 4-wire resistance, frequency,
continuity and diode tests.
Math functions dBm, Min/Max, Relative,
Compare, Hold and Percentage** are also avail-
able to ease your measurement analysis.
Not only are the U3400 Series built robust
for lasting reliability over the long haul, these
DMMs also ensure dependable measurements
with up to 0.012% basic DCV accuracy.
Efficient testing with dual display
and selectable resolutions*
Dual display on the U3400 Series lets you view
two parameters simultaneously as you measure,
and further enhances your troubleshooting
tasks. For example, theability to see both AC
voltage and frequency simultaneously would
help you to measure the frequency response of
amplifier circuits more efficiently and effectively.
Refer to Page 3 for more typical dual display
combinations and applications.
Physical security
Your instruments may be at risk of theft or
misplacement whenever you leave them unat-
tended on the bench. With the U3400 Series’
rear Kensington lock slot, you can secure your
DMM and be assured that it is where you
expect it to be for your continued testing the
next day.
Up to three measurement speeds are available
on the U3402A: Slow, Medium and Fast. This
means greater flexibility in catering to different
testing needs: a faster measurement speed at
lower resolution or a higher resolution at slower
measurement speed.
Up to 120,000 counts resolution
Up to 0.012% basic DCV accuracy
11 basic measurements and up to
six built-in math functions
Dual display on bright VFD
Selectable resolutions for variable
measurement speeds*
Kensington lock slot security
* U3402A only
** U3401A only
Page view 0
1 2 3 4 5 6 ... 18 19

Summary of Contents

Page 1 - Digital Multimeters

Agilent U3400 Series 4½ and 5½ Digit Digital MultimetersBasic + Good = Elegant SimplicityData SheetFeaturesSimply right for your basic needs, without

Page 2 - Take a closer look

10[1] To reduce noise interference that may be induced by the test leads, we recommend using a shielded test cable for measuring resistances above 500

Page 3

11[1] Specified accuracy at input >5% of full scale. Frequency Frequency resolution, full-scale reading and accuracy [± (% of reading + count)] Di

Page 4 - U3400 Series specifications

12[1] Auto ranging is used when dBm operation is selected.[2] In VDC 1000 V range, 1200 V is readable. In VAC 750 V range, 1000 V is readable.[3] Read

Page 5 - U3402A 5.5-digit DMM

13Full-scale display countsSupplemental measurement specifications Supplemental specifications Model Reading rate Display counts U3401A N/A 51

Page 6

14Supplemental measurement specifications Measurement SpecificationAC+DC voltageMeasurement method AC+DC coupled true RMS: measures the AC compon

Page 7 - DC current

15Supplemental measurement specifications Measurement SpecificationResistance Input protection 500 VResponse time U3401A• Approximately 1.5 s

Page 8

16Supplemental measurement specifications [1] Reference impedance is displayed on the secondary display.[2] Reading is displayed in watts (audio powe

Page 9

 17Power supply• 100 V/120 V/220 V/240 V ± 10%• AC line frequency 50 Hz to 60 HzPower consumption16 VA maximumInput power optionManu

Page 10 - Resistance

Each U3400 Series includes these standard shipped accessories:Accessories34138A Test Lead Kit 11059A Kelvin Probe Set U3400A-1CM Rack Mount KitU1161A

Page 11 - Diode test/continuity

myAgilentmyAgilentwww.agilent.com/find/myagilentA personalized view into the information most relevant to you.www.axiestandard.orgAdvancedTCA® Extensi

Page 12 - Decibel (dB) calculation

Take a closer lookPrimary displaySecondary displayInput terminals and current fuseAC linevoltage selectorLine voltage fuseselection tableAC powerconne

Page 13 - Supplemental specifications

3Typical dual display combinations and applications Primary display Secondary display Application Available inDCV ACV• Testing of DC-to-AC or AC-to-DC

Page 14 - • 0.01 W for 12 A range

[1] Input impedance is in parallel with capacitance <100 pF. [2] In VDC 1000 V range, 1200 V is readable with audio warning.[1] Input impedance is

Page 15

5[1] Accuracy specified at input >5% of full scale.[2] Input voltage <200 V RMS.[3] For 5 kHz to 10 kHz, accuracy is 0.7% + 15.[4] In VAC 750 V r

Page 16

6[1] Accuracy specified at input >5% of full scale.[2] Input voltage <200 V RMS.[3] In VAC 750 V range, 1000.0 V RMS is readable with audio warni

Page 17 - General characteristics

7[1] Typical at full-scale reading and voltage across the input terminals. [2] In 10 A range, >10 to 20 ADC is readable for 20 seconds maximum with

Page 18 - Ordering Information

8[1] Accuracy specified at input >5% of full scale and >1 A for 10 A range unless otherwise stated.[2] Typical at full-scale reading and voltage

Page 19 - (BP-09-27-13)

9[1] Accuracy specified at input >5% of full scale and >1 A for 10 A range unless otherwise stated.[2] Typical at full-scale reading and voltage

Comments to this Manuals