Agilent N518xA, E8663B, E44x8C, and E82x7D Signal Generators Programming Guide 341
Creating and Downloading User-Data Files
Data Transfer Troubleshooting (N5182A, E4438C and E8267D Only)
Requirement for Continuous User File Data Transmission
“Integer Number of Timeslots” Requirement for Multiple-Timeslots
If a user file fills the data fields of more than one timeslot in a continuously repeating framed
transmission, the user file is restarted after the last timeslot containing completely filled data fields.
For example, if the user file contains enough data to fill the data fields of 3.5 timeslots, the firmware
loads 3 timeslots with data and restart the user file after the third timeslot. The last 0.5 timeslot
worth of data is never modulated.
To solve this problem, add or subtract bits from the user file until it completely fills an integer
number of timeslots
“Multiple-of-8-Bits” Requirement
For downloads to bit and binary memory, user file data must be downloaded in multiples of 8 bits
(bytes), since SCPI specifies data in bytes. Therefore, if the original data pattern’s length is not a
multiple of 8, you need to:
add bits to complete the ASCII character
replicate the data pattern to generate a continuously repeating pattern with no discontinuity
truncate the excess bits
NOTE The “multiple- of- 8- bits” data length requirement is in addition to the requirement of
completely filling the data field of an integer number of timeslots.
Using Externally Generated, Real-Time Data for Large Files
When the data fields must be continuous data streams, and the size of the data exceeds the available
PRAM, real- time data and synchronization can be supplied by an external data source to the
front-panel DATA, DATA CLOCK, and SYMBOL SYNC connectors. This data can be continuously
transmitted, or can be framed by supplying a data-synchronous burst pulse to the EXT1 INPUT
connector on the front panel. Additionally, the external data can be multiplexed into internally
generated framing
PRAM Download Problems
Table 8-13 PRAM Download - Symptoms and Causes
Symptom Possible Cause
The transmitted pattern is interspersed
with random, unwanted data.
Pattern reset bit not set.
Insure that the pattern reset bit (bit 7, value 128) is set on the last byte of your
downloaded data.
Page view 350