Specifications
Table A-1 lists the specifications for the different load models. Specifications indicate warranted performance in
the 25°C ±5°C region of the operating temperature range. Specifications apply to normal and transient modes
unless otherwise noted.
Table A-1. Specifications
N3302A N3303A N3304A N3305A N3306A
Input Ratings
Current 0 - 30 A 0 - 10 A 0 - 60 A 0 - 60 A 0 - 120 A
Voltage 0 - 60 V 0 - 240 V 0 - 60 V 0 - 150V 0 - 60V
Maximum Power @ 40°C
1
150 W 250 W 300 W 500 W 600 W
Input Characteristic
Voltage
Max Power Contour
0
full
scale
OPERATING CONTOUR
0
DERATED CURRENT DETAIL
1
2
3
all specifications apply
slew rate limitations apply
Current Current
Voltage
(see Table A-2)
full
scale
full
scale
Specified Current @
Low Voltage Operation
2.0 V 30 A 10 A 60 A 60 A 120 A
1.5 V 22.5 A 7.5 A 45 A 45 A 90 A
1.0 V 15 A 5 A 30 A 30 A 60 A
0.5 V 7.5 A 2.5 A 15 A 15 A 30 A
0 V 0 A 0 A 0 A 0 A 0 A
1
Maximum continuous power available is derated linearly from 100% of maximum at 40°C, to 75% of maximum at 55°C.
Typical Minimum Operating Voltage @ Full Scale Current
N3302A N3303A N3304A N3305A N3306A
Table A-1 states that maximum
current is available down to 2
volts. Typically, under normal
operating conditions, the load
can sink the maximum current
down to the following voltages:
1.2 V 1.2 V 1.2 V 1.4 V 1.4 V
Page view 67