Agilent Technologies 8922M User's Guide Page 108

  • Download
  • Add to my manuals
  • Print
  • Page
    / 384
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 107
7-6
Bit Error Test Commands (Measure Subsystem)
CRC:COUNt
CRC:COUNt
Description Sets the CRC COUNt MEASurement attributes. Queries the CRC COUNt (completed),
Syntax MEASure:BETest:CRC:COUNt<n>?
MEASure:BETest:CRC:COUNt<n>[:MM-MOD] | [:AVG]
Options where <n> = 1..4.
Refer to Appendices E and F.
CRC:ICOunt
Description Setsthe CRC IntermediateCOunt MEASurement attributes.Queries the CRCIntermediate
COunt (completed).
NOTE: This can only be queried when in the state
TRIGger:BETest:MODE ‘RUN’
Syntax MEASure:BETest:CRC:ICOunt<n>?
MEASure:BETest:CRC:ICOunt<n>[:MM-MOD] | [:AVG]
Options where <n> = 1..4.
Refer to Appendices E and F.
CRC:IRATio
Description Sets CRC Intermediate RATio MEASurement attributes. Queries the CRC Intermediate
RATio
GPIB units are % (PCT), PPM; default unit is PPM.
Display units are % (PCT), PPM; default unit is PPM.
NOTE: This can only be queried when in the state
TRIGger:BETest:MODE ‘RUN’
Syntax MEASure:BETest:CRC:IRATio<n>?
MEASure:BETest:CRC:IRATio<n>[:MM] | [:AVG]
Options where <n> = 1..4.
Refer to Appendices D and F.