Agilent 81110A
Agilent 81100 Family of
Pulse Pattern Generators
Data Sheet – Version 1.3
Flexible Pulses or Patterns for Digital
Designs – Key Features
Pattern mode on all models from 80 MHz to 660 MHz,
including pseudo-random binary sequence
The outputs of dual-channel instruments can be added
(analog or EXOR, depending on model)
User-retrofittable channels for most models
• Upward compatibility
Individual solutions for frequencies up to 50, 80, 165, 330,
400 and 660 MHz
100% form/fit compatibility
Signals for testing digital designs and
components
The Agilent 81101A, 81104A, 81110A and 81130A generate all
the standard pulses and digital patterns needed to test current
logic technologies (CMOS, TTL, LVDS, ECL, etc.).
With the optional second channel on all of the models from
80 MHz to 660 MHz, multi-level and multi-timing signals can
be obtained using the internal channel addition feature.
Variable pulse parameters in pattern mode as well as in
pulse mode (not on the 81130A)
• Synchronously triggerable
Simulation of reflections/distortions
• (81104A, 81110A)
Three/four-level codes (81104A, 81110A)
Page view 0
1 2 3 4 5 6 ... 12 13

Summary of Contents

Page 1 - Pulse Pattern Generators

Agilent 81110AAgilent 81100 Family ofPulse Pattern GeneratorsData Sheet – Version 1.3 Flexible Pulses or Patterns for Digital Designs – Key Features•

Page 2

Data Sheet 81100 Family of Pulse Pattern GeneratorsDigital channel additionChannel 1 can be logically combined with channel 2 (XOR) as shown in Figure

Page 3 - 81101A Specifications

Data Sheet 81100 Family of Pulse Pattern Generators11Common SpecificationsUser interface Overprogramming: All parameters can be overprogrammed (exceed

Page 4

Data Sheet 81100 Family of Pulse Pattern Generators12Ordering Information - 81100 FamilyThe minimum configuration for a working instrument consists of

Page 5 - Timing characteristics

For more information, please visit us at www.agilent.com/find/pulse_generatorFor the latest version of this document, please visit our website at:

Page 6 - ± 19 V level window

Glitch-free timing changes Timing values can now be swept without the danger of misleading pulses or dropouts that could cause measurement errors. (Ap

Page 7 - Inputs and Outputs

81101A SpecificationsBurst Count: 2 to 65536 (single or double pulses).Delay: Delay, phase or % of period.Double pulse delay: Double pulse and delay a

Page 8 - 81130A Specifications

Data Sheet 81100 Family of Pulse Pattern GeneratorsLevel/Pulse Performance Characteristics Level specifications are valid after a 30 ns typical settl

Page 9 - Pattern and sequencing

81104A and 81110A SpecificationsBurst count: 2 to 65536 (single or double pulses).Delay: Delay, phase or % of period.Double pulse and delay: Mutually

Page 10 - Trigger output

Level/Pulse Performance Characteristics Level parameters: voltage or current, high or low level, offset or amplitude.On/off: relays connect/ disconnec

Page 11 - Specifications

Data Sheet 81100 Family of Pulse Pattern GeneratorsPattern modePattern length: 16 kbit/channel and strobe output. Output format: RZ (return to zero),

Page 12 - Agilent 81101A

Data Sheet 81100 Family of Pulse Pattern Generators881130A SpecificationsTiming characteristics Measured at 50% amplitude at fastest transitions in co

Page 13 - Revised: October 1, 2009

Data Sheet 81100 Family of Pulse Pattern GeneratorsLevel/Pulse Performance Characteristics Level specifications are valid after a 30 ns typical settli