Agilent Technologies 83640A Specifications

Browse online or download Specifications for Multimeters Agilent Technologies 83640A. Agilent Technologies 83640A Specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Network Analyzer

8510C45 MHz to 110 GHzAgilent 8510CNetwork AnalyzerData Sheet

Page 2 - Network Analysis

10Agilent 8510XF system performanceE7350A Option 005 (45 MHz to 110 GHz)The following specifications describe the system performance of the 8510XF sys

Page 3

11Reflection measurementsTransmission measurementsMagnitude PhaseMagnitude PhaseMagnitude PhaseMagnitude PhaseMeasurement uncertainty

Page 4 - System performance

12Agilent 85108A Pulsed-RF System2 to 20 GHzThe following specifications describe the system performance for the 8510C network analyzer in 85108A conf

Page 5 - Agilent 8510SX

13Agilent 8511A/8511B frequency converters45 MHz to 26.5 GHz/45 MHz to 50 GHzDescriptionCombining the 8511A or 8511B frequency converter withthe 8510C

Page 6 - Agilent 85107B Option 005

14Accuracy considerations when usingramp sweepThe uncertainty values for the preceding systems assumethat the microwave source operates in the synthes

Page 7 - Agilent 85106D

15MeasurementNumber of display channels: Two display channels areavailable.Number of display parameters: The four basic param-eters, S11, S21, S12, S2

Page 8

16Power sweep: From power domain, sweep power at a CW frequency. When combined with the receiver calibration feature, power sweep allows quicker and m

Page 9

17Thru-reflect-line (TRL): A two-port calibration whichrequires a through connection, a reflection standard, anda reference transmission line. S-param

Page 10

18StorageInternal memoryInstrument state: Eight instrument states can be storedin non-volatile memory via the SAVE menu. They can thenbe recalled via

Page 11 - Measurement uncertainty

19Bandpass impulse: The bandpass impulse simulates apulsed RF signal (with an impulse envelope) and is usedto measure the time domain response of band

Page 12 - 45 MHz to 2 GHz

ContentsPageSystem performance characteristics . . . . . . . . .3Major Agilent Technologies 8510 NetworkAnalyzer Systems8510E, Option 005, 45 MHz to

Page 13

20The factory selected addresses are the following:8510C network analyzer 16Source #1 19Source #2 18Test set 20Plotter 05Printer 01Disc drive 00Pass-t

Page 14

21System SoftwareAgilent 85161B measurement automation softwareDescription: This software is designed specifically tooperate on an HP 9000 Series 200

Page 15 - System capabilities

22S-parameter test setsDescriptionCombining the 8510C network analyzer with an 8514B, 8515A, or 8517B results in a system for makingfull S-parameter m

Page 16

23Agilent 8510C accessoriesA wide range of accessories support the 8510C network analyzer including calibration kits, verificationkits, cables and ada

Page 17 - Display control

24Electronic calibrationElectronic calibration (ECal) is a precision, single connec-tion, one- or two-port calibration technique that uses fullytracea

Page 18 - Time domain (Option 010)

25Verification kitsVerification kits are used to verify that a network analyzer is operating within its specified performance.Agilent Technologies off

Page 19 - Remote programming

26Test port return cable specificationsSingle cables for the 8514B and 8515A test sets (3.5 mm)Connector type Frequency Length2Return Insertion loss

Page 20 - Environmental

27Related literature5091-8970E Agilent 8510 Network Analyzer Color Brochure5965-8837E Agilent 8510 System Solutions 5091-8967E Agilent 8510 Family Net

Page 21 - System Software

Agilent Technologies’ Test and Measurement Support, Services, and AssistanceAgilent Technologies aims to maximize the value you receive, whileminimizi

Page 22 - S-parameter test sets

3System performance characteristicsThis data sheet offers two types of performance numbersto describe the merit of any measurement system: specificati

Page 23 - Agilent 8510C accessories

4Agilent 8510E Option 00545 MHz to 20 GHzThe following specifications describe the system performance for the 8510C network analyzer in the 8510EOptio

Page 24 - Electronic calibration

5Agilent 8510SX45 MHz to 26.5 GHzThe following specifications describe the system perfor-mance for the 8510C network analyzer with the 8510SXconfigura

Page 25

Agilent 85107B Option 00545 MHz to 50 GHzThe following specifications describe the system performance for the 8510C network analyzer in the 85107B Opt

Page 26

7Agilent 85107B Options 005 and 00745 MHz to 50 GHzThe following specifications describe the system performance for the 8510C network analyzer in the8

Page 27 - Related literature

8Agilent 8510XF system performanceE7340A Option 005 (45 MHz to 85 GHz)The following specifications describe the system performance of the 8510XF syste

Page 28 - 5091-8484E

9Reflection measurementsTransmission measurementsMagnitude PhaseMagnitude PhaseMagnitude PhaseMagnitude PhaseMeasurement uncertainty