Programming Command Reference
TESTs Subsystem for MANUAL TEST
3. Programming Command
Reference
Command Reference for MS Information
MS Information
TESTs:MANual:RESults:MSINformation:IMSI?
This query command returns the IMSI string of 15 letters.
TESTs:MANual:RESults:MSINformation:IMEI?
This query command returns the IMEI string of 15 letters.
TESTs:MANual:RESults:MSINformation:DIAL?
This query command returns the 20-digit dialed number string.
TESTs:MANual:RESults:MSINformation:PCLass?
This query command returns a 1-digit power class string.
TESTs:MANual:RESults:MSINformation:GVERsion?
This query command returns a 1-digit version number of the GSM mobile under
test.
NOTE For Test Sets with Option 002, if the mode is set to ASYNC, these
commands are invalid.
For Test Sets with Option 040, if the mode is set to GPRS, the
commands for DIAL and GVERsion are invalid.
Command Reference for Peak TX Power /Burst Timing/Power Ramp
Measurement Screen
The TPOWer and TXAMplitude commands are used to set or read the controls and
parameters associated with the Peak TX Power/Burst Timing/Power Ramp
measurements and the pass/fail tests.
Send the "DISPlay:MANual:TPOWer" command to display the Peak TX
Power/Burst Timing/Power Ramp screen for MANUAL TEST before sending the
following commands.
DCS1800 GSM900 1710200000 to 1784800000;
890200000 to 914800000
1710200000
E-GSM 1710200000 to 1784800000;
880200000 to 914800000
OFF 1710200000 to 1784800000
PCS1900 OFF 1850200000 to 1909800000 1850200000
RFORmat MBANd Allowable Range [Hz] Preset Value [Hz]