Agilent Technologies E6392B User's Guide Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 206
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
30 Chapter 2
Using Functions
Testing a Dual Band Mobile with AUTOMATIC TEST
Step 6. Set the highlighted fields of the test parameters as shown in the above screen. The
first three traffic channels in TCH are for GSM900 and the last three for DCS1800,
respectively.
If you want to supply dc power from the Test Set to the mobile, set the DC Power
field to Auto or On and enter your desired voltage value. To do this, use the
Universal DC Power Adapter and an appropriate dc power cable to connect
between the AUX connector of the Test Set and the mobile.
Step 7. Press Return, CONFIGURATION, Test Setup, then Test Sequence to obtain the
Test Setup: Test Sequence screen shown below.
Step 8. Enter BS in the second step of the test flow, then notice that the fifth step changes
to BS Release, the sixth to MS Call, and the seventh to MS Release.
Enter MS in the second step of the test flow again.
Step 9. Enter GSM900 and DCS1800 in Radio Standard and Multi Band, respectively, and
set other fields as shown in the illustration in Step 7.
Step 10. Enter Run in each field of the LOC. Update, Talk and BS Call steps.
Step 11. Enter Run in each cell of the test item table.
Step 11
Step 10
Step 8
Page view 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 205 206

Comments to this Manuals