4XLFN5HIHUHQFH*XLGHSCPI Command SummaryThe following conventions are used for SCPI command syntax for remoteinterface programming:•
Mx+B Scaling Commands (see page 244 in the User’s Guide)CALCulate :SCALe:GAIN <gain>[,(@<ch_list>)] :SCALe:GAIN? [(@<ch_list>)]
Digital Input Commands (see page 255 in the User’s Guide)Ch 01DIO (LSB)Ch 02DIO (MSB)Ch 03TotalizerCh 04DACCh 05DACCONFigure:DIGital:BYTE (@<scan_
Switch Control Commands (see page 259 in the User’s Guide)ROUTe :CLOSe (@<ch_list>) :CLOSe:EXCLusive (@<ch_list>) :CLOSe? (@<ch_lis
System-Related Commands (see page 264 in the User’s Guide)SYSTem :DATE <yyyy>,<mm>,<dd> :DATE? :TIME <hh>,<mm>,<s
Status System Commands (see page 286 in the User’s Guide)*STB?*SRE <enable_value>*SRE?STATus :QUEStionable:CONDition? :QUEStionable[:EVENt]?
Service-Related Commands (see page 294 in the User’s Guide)INSTrument :DMM {OFF|ON} :DMM? :DMM:INSTalled?DIAGnostic :DMM:CYCLes? :DMM:CYCLes:CL
Agilent 34901A 20-Channel Multiplexer (see page 164 in the User’s Guide) Agilent 34902A 16-Channel Multiplexer (see page 166 in the User’s Guide)
Agilent 34903A 20-Channel Actuator (see page 168 in the User’s Guide) Agilent 34904A 4x8 Matrix (see page 170 in the User’s Guide)17
Agilent 34905A/6A Dual 4-Channel RF Multiplexers (see page 172 in the User’s Guide) Agilent 34908A 40-Channel Single-Ended Multiplexer (see p
Agilent 34907A Multifunction Module (see page 176 in the User’s Guide)19
Scan Measurement Commands (see page 226 in the User’s Guide)MEASure :TEMPerature? {TCouple|RTD|FRTD|THERmistor|DEF} ,{<type>|DEF}[,1[,{&l
Factory Reset State The table below shows the state of the instrument after a FACTORY RESETfrom the Sto/Rcl menu or *RST command from the remote int
Scan Configuration Commands (see page 226 in the User’s Guide)ROUTe :SCAN (@<scan_list>) :SCAN? :SCAN:SIZE?TRIGger :SOURce {BUS|IMMediate|E
Scanning With an External Instrument (see page 239 in the User’s Guide)ROUTe :SCAN (@<scan_list>) :SCAN? :SCAN:SIZE?TRIGger :SOURce {BUS|I
Temperature Configuration Commands (see page 219 in the User’s Guide)CONFigure :TEMPerature {TCouple|RTD|FRTD|THERmistor|DEF} ,{<type>|DEF
Voltage Configuration Commands (see page 223 in the User’s Guide)CONFigure :VOLTage:DC [{<range>|AUTO|MIN|MAX|DEF} [,<resolution>|MI
Resistance Configuration Commands (see page 224 in the User’s Guide)CONFigure :RESistance [{<range>|AUTO|MIN|MAX|DEF} [,<resolution>
Current Configuration Commands (see page 224 in the User’s Guide) Valid only on channels 21 and 22 on the 34901A multiplexer module.CONFigure :CURRe
Frequency and Period Configuration Commands (see page 214 in the User’s Guide)CONFigure :FREQuency [{<range>|AUTO|MIN|MAX|DEF} [,<reso