Upgrade Kits
Upgrade kits for the PNA Series
E8362B, E8363B, E8364B, E8361A, N5250A
3
Upgrade kits are available to add options after initial purchase. To
order an upgrade kit for the PNA series, order the analyzer’s model
number followed by a “U”, then indicate the option to be added (for
example, E8362BU-010). The serial number of the instrument to be
retrofitted is required as part of the order.
Time-domain (Option 010)
User installable.
Configurable test set (Option 014)
Provides six front-panel RF access loops.
Includes installation at an Agilent service center.
Receiver attenuators (Option 016)
Includes installation at an Agilent service center.
Extended memory (Option 022)
Applies only to E8362B/63B/64B/61A with 256 MB of RAM.
Includes installation at an Agilent service center.
Frequency range upgrade to an E8363B (40 GHz) PNA
(Option 040/041)
Available only for the E8362A/B. Includes
installation at an Agilent service center.
Frequency range upgrade to an E8364B (50 GHz) PNA
(Option 050/051)
Available only for the E8362A/B and E8363A/B.
Includes installation at an Agilent service center.
Frequency range upgrade to an E8361A (67 GHz) PNA
(Option 067/068))
Available only for the E8363B and E8364B.
Includes installation at an Agilent service center.
Frequency-offset (Option 080)
Includes installation at an Agilent service center.
External reference switch (Option 081)
Includes installation at an Agilent service center.
Scalar-calibrated converter measurements (Option 082)
User installable. Option 080 required.
Frequency converter measurement application (Option 083)
User installable. Option 080 and 081 required.
Embedded LO Measurements (Option 084)
Advanced software tuning that provides absolute group delay of
converters with embedded LOs without the need for access to a
common reference signal. The measurement result is the same
as locking the DUT LO to the reference mixer LO. (Options 080
and 083 required) Requires firmware A.07.05 and above plus
1.1 GHz CPU board.
4-Port measurement application (Option 550)
Enables full 4-port error correction and differential
measurements. Option 014 and external test set required.
User installable.
N-port capabilities (Option 551)
Adds full N-port error correction and measurement
capabilities. Option 014 and external test set required.
User installable.
Extended power range (Option UNL)
Adds a step attenuator and a bias-tee between source and
each test port. Includes installation at an Agilent service center.
Pulsed-RF measurement capability (Option H08)
Provides software to set up and control pulsed-RF
measurements using narrowband detection, with point-in-pulse
and pulse-profile capability. User installable.
IF access (Option H11)
Provides hardware for antenna, point-in-pulse, and millimeter-
wave measurements. Adds rear-panel RF and LO outputs,
external IF inputs, and IF gates (gates enabled with Option H08).
Includes installation at an Agilent service center.
High-power test set (Option H85)
1
Removes bias tees for higher test port power-handling capability.
Options UNL, 014, 016, 080, and 081 are required. Includes
installation at an Agilent Service Center.
Upgrade to C model
2
(Option 221 or Option 241)
Provides new front panel, new hard drive with latest firmware and
new GUI. Option 221 is available for the E8361A, E8362/3/4B,
and N5230A 2-port instruments. Option 241 is available for
N5230A 4-port instruments.
1. Please contact Agilent for ordering this upgrade.
2. Some older PNAs may also require the purchase of a new CPU board.
3. For N5250A upgrades, order E8361AU options.