PNA-X Network Analyzers N5242A , 10 MHz to 26.5 GHz, 2 or 4 Ports
Options
To add options to a product, order the corresponding item number.
Description For N5242A Additional information
Test set
Option 200 2 ports, single source N5242A-200
Option 224 2 ports, add internal 2nd source, combiner and mechanical switches N5242A-224 Requires Options 200, 219 and 080
Option 400 4 ports, dual source N5242A-400 Recommends Option 080
Option 423 4 ports, add internal combiner and mechanical switches N5242A-423 Requires Options 400, 419, and 080
Power configuration
Option 219 2 ports, extended power range and bias-tees N5242A-219 Requires Option 200
Option 419 4 ports, extended power range and bias-tees N5242A-419 Requires Option 400
Option H85 High-power configuration N5242AH85
Measurement applications
Option 010 Time-domain measurements N5242A-010
Option 029
1
Fully-corrected noise figure measurements N5242A-029 Requires one of these options: 219,
224, 419 or 423
Option 080 Frequency offset N5242A-080
Option 082
2
Scalar-calibrated converter measurements N5242A-082 Requires Option 080
Option 083
2
Vector- and scalar-calibrated converter measurements N5242A-083 Requires Option 080
Option 084 Embedded LO measurements N5242A-084 Requires Options 080 and 083,
requires firmware A.07.50 and above
Option 086 Gain compression application N5242A-086 Recommend Options 219 or 419,
requires firmware A.08.00 and above
Option 551
3
N-port capabilities N5242A-551
Pulse, antenna, mm-wave
Option H08 Pulse measurements N5242A-H08 Requires Option 025
Option 020 Add IF inputs for antenna and mm-wave N5242A-020
Option 021 Add pulse modulator to internal 1st source N5242A-021
Option 022 Add pulse modulator to internal 2nd source N5242A-022 Requires Options 224 or 400
Option 025 Add four internal pulse generators N5242A-025
Accessories
Option 1CM Rack mount kit for use without handles N5242A-1CM
N1966A Pulse I/O adapter N1966A
N4688A USB CD R/W drive N4688A
N4689A USB Hub N4689A
Calibration Software
Option 897
4
Perpetual license for built-in performance test software for N5242A-897
Agilent inclusive calibration
Option 898
4
Perpetual license for built-in performance test software for N5242A-898
standards compliant calibration
Calibration documentation
Option 1A7 ISO 17025 compliant calibration N5242A-1A7
Option UK6 Commercial calibration certificate with test data N5242A-UK6
Option A6J ANSI Z540 compliant calibration N5242A-A6J
1. In addition to the list of required PNA-X options, Option 029 requires an N4691B ECal module for use as an impedance tuner,
and an Agilent 346 series noise source for calibration.
2. Option 082 is a subset of Option 083, and therefore, they can not be ordered together.
3. When configured as a multiport analyzer with Option 551, the combiner feature of Option 224 or 423 is not available.
When configured as a standalone analyzer, the combiner feature is available.
4. Additional hardware required. Please refer to chapter 2 of the Service Guide for required service test equipment.
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 37 38

Comments to this Manuals

No comments