Agilent Technologies U2802A User Manual Page 58

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 57
58
U2741A
Product characteristics and general specifi cations
REMOTE INTERFACE
Hi-Speed USB 2.0*
USBTMC-USB488
[1]
POWER CONSUMPTION
+12 VDC, 2 A maximum
Isolated ELV supply source
OPERATING ENVIRONMENT
Operating temperature from 18 °C to +28 °C
Relative humidity at 50% RH (non-condensing)
Altitude up to 2000 meters
Pollution Degree 2
For indoor use only
STORAGE COMPLIANCE
Storage temperature from –20 °C to 70 °C
Relative humidity at 5% to 90% RH (non-condensing)
SAFETY COMPLIANCE
Certifi ed with:
IEC 61010-1:2001/EN 61010-1:2001 (2nd Edition)
USA: ANSI/UL 61010-1:2004
Canada: CSA C22.2 No.61010-1:2004
EMC COMPLIANCE
IEC 61326-1:2002/EN 61326-1:1997+A2:2001+A3:2003
Canada: ICES-001:2004
Australia/New Zealand: AS/NZS CISPR 11:2004
MEASUREMENT COMPLIANCE
CAT II 300 V Over-voltage protection
COMMON MODE REJECTION RATIO (CMRR)
DC CMRR > 120 dB with 1k unbalanced load
AC CMRR > 70 dB at 50/60 Hz ±0.1% with 1k unbalanced load
NORMAL MODE REJECTION RATIO (NMRR)
> 60 dB at 50/60 Hz ±0.1%
[2]
> 0 dB at 50/60 Hz ±0.1%
[3]
SHOCK AND VIBRATION
Tested to IEC/EN 60068-2
IO CONNECTOR
Four banana socket terminals
DIMENSION (W × D × H)
Module dimension:
117.00 mm × 180.00 mm × 41.00 mm (with bumpers)
105.00 mm × 175.00 mm × 11.50 mm (without bumpers)
WEIGHT
509 g (with bumpers)
451 g (without bumpers)
WARRANTY
One year for U2741A
Three months for standard shipped accessories
CALIBRATION
Calibration interval of one year is highly recommended
Product outlook and dimensions
Front view
Rear view
Top view
Standard shipped accessories
12 V, 2 A AC/DC Power adapter
Power cord
Standard test lead set
USB Standard-A to Mini-B interface
cable
L-Mount kit (used with modular
product chassis)
Agilent USB Modular Products Quick
Start Guide
Agilent Measurement Manager Quick
Reference Card
Agilent USB Modular Products
Reference CD-ROM
Agilent Automation-Ready CD-ROM
(contains the Agilent IO Libraries Suite)
Certifi cate of Calibration
Optional accessories
E2308A Thermistor temperature probe
USB Secure 2-m cable
41.00 mm
117.00 mm
180.00 mm
8.60 mm
[1]
Compatible with Microsoft Windows operating systems only.
[2]
Applicable for NPLC > 1.
[3]
Applicable for NPLC 0.2 and 0.02
*If remote connections are necessary, a E5813A USB/LAN hub can be used. Please go to the
product’s user guide for more information.
Page view 57
1 ... 57 58 59 ... 74

Comments to this Manuals

No comments