Protocol Analyzer
Working with Configuration Files
400 5967–9446
To save filter/settings in a file
1 Choose File➤Save Filter/Settings… from the base
window.
2 Specify the file in which to save the current filter/
settings.
When you save settings, all of the items configured with the Settings and
Filter menus are saved in the file you specify. These items include timer
settings, capture buffer settings and interface, as well as the current
filter.
To have the current filter/settings be Protocol Analyzer’s default values,
save them in the file name protanal.default in the NetMetrix search
path. The search path is the current directory, the environment variable
NETM_DIR, program_path/../config, and /usr/netm/config.
A settings file can also be used when starting or arming an instance from
the command line.
See Also Settings menu items: pages 356 – 358.
Filter menu items: pages 360 – 379.
“To start an instance” on page 353.
“To arm an instance” on page 355.
To load a filter/settings file
1 Choose File➤Load Filter/Settings… from the base
window.
2 Specify the filter/settings file to load.