Page view 449
Alarms and Traps
Setting Alarms
5967–9446 449
Figure 94 shows the relevant parts of the Configure Alarm and Alarm
Advanced Options windows for this alarm.
When the alarm triggers, the agent logs the event, then sends a trap to
your management station, which executes a script that notifies you. In
addition, the agent starts capturing all CRC alignment error packets for
analysis.
When the alarm rearms, the agent logs the event, sends a trap and exe-
cutes a script that notifies you via electronic mail, and stops packet
capture. You can then use Protocol Analyzer to examine the captured
packets.
Figure 94 Example: Alarm on CRC Error Packets with Packet Capture
Configure Alarm
Alarm Advanced
Options
Packet capture
instance “CRC errors/
alarm” starts when
alarm triggers
Capture stops when
alarm rearms
Script displays a
dialog box when trap
is sent
Script sends email
when trap is sent
Page view 449