Network analyzer
test set
Network analyzer
test set
Test port
adapter
Device
under
test
Single cable
Device
under
test
Cable set
Measurement Accessories
A complete list of RF and microwave test accessories
is available on our Web site:
www.agilent.com/find/accessories
Accessories are available in these connector types:
50 ohm Type-N, 3.5 mm, 7 mm, 2.4 mm, 2.92 mm, 1.85 mm, 1.0 mm,
and waveguide. Test port cables and a calibration kit should be
added for a complete measurement system. A verification kit is
used to verify corrected system performance.
Cables and adapter sets
Agilent offers cables in the following types:
single cables in semi-rigid and flexible
cable sets in semi-rigid and flexible
There are also adapter sets available that protect the test port
and convert the port to the desired connector interface. These
kits contain:
one male adapter
one female adapter
To attain the best mechanical rigidity for device connection, use
a single cable and the appropriate special adapter set. To attain
the greatest flexibility for device connection, use a cable set.
Calibration kits
Coaxial measurements
Mechanical calibration kits include standards, such
as opens, shorts and loads, which are measured by the network
analyzer for increased measurement accuracy.
Electronic calibration (ECal) kits replace mechanical calibration
standards with one solid-state calibration module that is controlled
by the network analyzer via USB, to present many different
impedances to the test ports. A full two-port calibration can be
performed quickly with a single connection. This technique
reduces operator errors and connector wear and abrasion.
Choose a calibration kit for each connector type to be used.
Economy, includes:
open standards (male and female)
short standards (male and female)
fixed-termination standards (male and female)
Standard, includes the devices in the economy kit and adds:
sliding load standards (male and female) or a series of
offset shorts
Precision, includes the devices in the economy kit and adds:
50 ohm airline(s) for TRL calibration
TRL adapters
Waveguide measurements
For waveguide measurements, Agilent offers mechanical calibration
kits that include:
waveguide-to-coax adapters (X, P, K, R, Q, U, V)
precision waveguide section
flush short circuit
fixed terminations
straight section