Z5623AH84 Pulsed S-parameter test set, 2 to 40 GHz
Includes two pin switches for bi-directional (forward and
reverse) pulsed-RF stimulus, and two directional couplers for
the reference channels. It does not include internal amplifiers,
but has front panel access loops for switching in external
amplifiers to boost port power in both directions.
Z5623AH86 Pulsed S-parameter test set, 2 to 40 GHz
Includes one pin switch to modulate the analyzer’s
internal source in the forward direction, and one directional
coupler for the reference channel. It does not include internal
amplifiers, but has front panel access loops for switching in
an external amplifier to boost port power.
Z5623AH87 Pulsed S-parameter test set, 1 to 50 GHz
Includes two pin switches for bi-directional (forward and
reverse) pulsed-RF stimulus. It does not include internal amplifiers,
but has front panel access loops for switching in external
amplifiers to boost port power in both directions.
Z5623AH89 Pulsed S-parameter test set, 10 MHz to 5 GHz
Includes one pin switch to modulate the analyzer’s
internal source in the forward direction. This test set has no
internal amplifier, no reference channel variable attenuator, and
no GPIB control (manual control only).
Z5623AH90 Pulsed S-parameter test set, 1 to 50 GHz
Same as Z5623AH87, but adds 50 GHz couplers to the front
panel to allow DUT connection on the test set instead of
using the PNA test ports.
Note: Pulse biasing can be achieved with or without the use
of a pulsed S-parameter test set. A proper pulse-bias driver
must be used. Contact your local Agilent Sales Representative
for additional pulsed S-parameter test set configurations and
details.
Peripherals
The following peripherals may be used with the Microwave PNA
Series. Other peripherals not listed here may also be compatible
with these instruments.
Monitors
VGA-compatible monitor
Printers
USB, LAN, parallel or serial printers with Microsoft® Windows®
printer driver
Interface cables
Choose the appropriate cables to connect each
peripheral to the network analyzer.
10833A GPIB cable, 1.0 m (3.3 ft)
10833B GPIB cable, 2.0 m (6.6 ft)
10833D GPIB cable, 0.5 m (1.6 ft)
82357B GPIB to USB interface
Applications
Material measurements
85070E High-Temperature Dielectric Probe Kit
The 85070E enables measurements of the dielectric properties
of materials quickly and conveniently. Measurements made
with this probe are nondestructive and require no sample
preparation. The dielectric probe is well suited for measurements
of liquid, semisolid and flat solid materials. Measurement
results can be viewed in a variety of formats (ε’
r
, ε”
r
, tan δ
or Cole-Cole). The supplied software can be run in the PNA
analyzer or on a PC.
85071E Materials Measurement Software
The 85071E materials measurement software calculates the
permittivity and permeability of material samples placed in a
coaxial airline or a rectangular waveguide. The measurement
technique works well for solid materials that can be machined
to fit precisely inside a transmission line. Measurement
results can be viewed in a variety of formats (ε’
r
, ε
r
, µ’
r
, µ”
r
, tan δ,
or Cole-Cole µ). The software can be run in the PNA analyzer
or on a PC.
Pulsed measurements
1
The pulsed RF measurement capability (Option H08) and IF access
(Option H11), are recommended for pulsed measurements with
the PNA Series.
Pulse/pattern generators
Recommended to provide pulse signals and timing to the pulsed
S-parameter text set and MW PNA
81104A Pulse/pattern generator, 80 MHz, single-/dual-channel
with one or two Agilent 81105A output modules.
81110A Pulse/pattern generator, 165 MHz, single-/dual-channel
with one or two Agilent 81111A output modules.
Note: Each pulse/pattern generator must be ordered with its
associated output modules depending on the measurement
configuration.
Pulsed S-Parameter test sets
Z5623AH81 Pulsed S-parameter test set, 2 to 20 GHz
Includes a pin-diode switch to modulate the analyzer’s
internal source, an amplifier, and directional coupler
to provide a pulsed reference to the analyzer.
Z5623AH83 Pulsed S-parameter test set, 2 to 20 GHz
Includes two pin switches for bi-directional (forward and
reverse) pulsed-RF stimulus, and two directional couplers for
the reference channels. It does not include internal amplifiers,
but has front panel access loops for switching in external
amplifiers to boost port power in both directions.
1. For more details regarding pulsed measurement configurations with the
PNA Series, refer to Agilent’s Web site (www.agilent.com/find/pna)
to download a copy of the Microwave PNA Series Network Analyzer
Configuration Guide for Pulsed Measurements, literature number 5988-9833EN.