Page view 432
Alarms and Traps
Setting Alarms
432 5967–9446
The RMON Alarms window contains the following items.
Probe Displays the names or IP addresses of the selected data sources. If
multiple data sources were selected, their names are separated with
spaces.
If you change the data sources in this field, push the Reload from
probe button to retrieve the alarm configuration from the new list.
Community Sets the community name to use when accessing the data sources. If no
community name is entered, community names in the Agent Manager
database are used. Specify at least a level-3 community name to
manage alarms on HP probes; otherwise, specify the write community.
Alarms Contains descriptions for the alarms configured on the selected data
sources.
Add… Displays the Configure Alarm window, allowing you to create a new
alarm. Refer to page 433 for details.
Modify… Displays the highlighted alarm in the Configure Alarm window,
allowing you to make changes. Refer to page 438.
Delete Removes the highlighted alarm. When you push Delete, the alarm is
removed immediately from the agent; you cannot undo this button’s
action except by recreating the alarm.
Reload from probe Retrieves all alarms from the specified data source(s).
Logs… Displays the log for the highlighted alarm. Refer to page 452.
Messages Shows any status and error messages from communication with the
data sources.