OUTPut:TTLTrgn[:STATe]?
OUTPut:TTLTrgn[:STATe]? queries if the specified VXIbus TTLTRG line is set to
be a source of trigger from the module.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
TTLTrg
n keyword 0 to 7 none
Returns: unsigned 16-bit integer (uint16).
Comments This query returns a 1 if the specified VXIbus TTLTRG line is enabled as a
trigger source. This query returns a
0 if the specified VXIbus TTLTRG line is
disabled as a trigger source.
Related Commands: OUTPut:TTLTn[:STATe]
OUTPutn[:STATe]
OUTPutn[:STATe] <state> opens or closes the specified channel output relay.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
OUTPut
n
keyword 1 to 8 or 1 to 16 none
<
state>
boolean OFF | ON | 0 | 1 none
Comments In the keyword, OUTPutn, the valid range of n is:
1 to 8 for E1418A, E1418A Option 002
1 to 16 for E1418A Option 001, E1418A Option 003.
Values of n outside these ranges will generate an error.
This command sets the output state of individual channel output relays. Use the
DIAGnostic:OUTPut:ALL[:STATe] command to set all channels with a single
command.
*RST Condition: All output relays open.
Related Commands: OUTPutn[:STATe]?, DIAGnostic:OUTPut:ALL[:STATe]