Agilent Technologies 16048A Specifications Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 104
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
16452A Liquid Dielectric Test
Fixture
Terminal Connector: 4-Terminal Pair, SMA
Dimensions (approx.): 85(H) x 85(W) x 37(D) [mm]
Weight (approx.): 1400 g
Measurement Accuracy: A + B + C [%]
Up to 110 MHz (4-Terminal Pair) Material
Description: This test fixture provides accurate dielectric
constant and impedance measurements of liquid materials. The
16452A employs the parallel plate method, which sandwiches
the liquid material between two electrodes to form a capacitor.
A LCR meter or an impedance analyzer is then used to measure
the capacitance created from the fixture.
Applicable Instruments: 4263B, 4284A*, 4285A, E4980A, (4294A)**
* denotes the instrument is obsolete.
** applicable in a limited frequency range.
Frequency: 20 Hz to 30 MHz
Operating Temperature: –20°C to 125°C
Maximum Voltage: 30 Vrms
Material Capacity: Required sample liquid capacity depends
on the gap of the electrodes.
Furnished Accessories:
Requires the following interface cables to connect to a measurement
instrument. Select accordingly to the required temperature conditions.
* Four BNC(m) to BNC(m) adapters (P/N 1250-0216) are needed to connect
the 16048G/H and 16452A.
Gap of electrodes 0.3 mm 0.5 mm 1 mm 2 mm
Air capacitance 34.9 pF 21.2 pF 10.9 pF 5.5 pF
±25% ±15% ±10% ±10%
Sample liquid capacity 3.4 ml 3.8 ml 4.8 ml 6.8 ml
Applicable frequency 20 Hz – 30 MHz
Description P/N Qty.
Shorting Plate 16092-08010 1 E
O-ring for Liquid Outlet 0905-1277 1 D
Spacer (1.3 mm thickness) 16452-00601 1 F
Spacer (1.5 mm thickness) 16452-00602 1 F
Spacer (2.0 mm thickness) 16452-00603 1 F
Spacer (3.0 mm thickness) 16452-00604 1 F
Lid of Liquid Outlet 16452-24002 1 G
SMA-BNC Adapter 1250-1200 4 H
Waterproof Cap for BNC Connector 1252-5831 4 I
Carrying Case 16452-60111 1
Operation and Service Manual 16452-90020 1
Angle Iron of Stand Body for Fixture Stand
16452-01201 2
Screw of Stand Body for Fixture Stand
0515-0914 4 C
Screw for Fixture Stand 0515-0914 4
Electrode (High and Low) NA 2
A,B
Electrode gap (mm) A (%)
0.3 0.005 × M.R.P
0.5 0.006 × M.R.P
1.0 0.008 × M.R.P
2.0 0.020 × M.R.P
Temperature Model# or P/N
Cable length
(approx.)
0°C to 55°C 16048A 0.94 m
–20°C to 125°C 16452-61601 1 m
–20°C to 150°C 16048G* for 4294A only 1 m
–20°C to 150°C 16048H* for 4294A only 2m
M.R.P is Measurement Relative Permittivity
Error B [%]
Error C [%] = Measurement Error of Instrument
4284A with 16452A
(A)
(H)
(B)
(I)
(C)
(F)
(E)
(D)
(G)
40
Page view 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 103 104

Comments to this Manuals