Chapter 13 289
SCPI Command Reference
E5061A/E5062A commands
13. SCPI Command
Reference
:CALC{1-4}:RLIM:DISP:SEL
Syntax :CALCulate{[1]|2|3|4}[:SELected]:RLIMit:DISPlay:SELect <numeric>
:CALCulate{[1]|2|3|4}[:SELected]:RLIMit:DISPlay:SELect?
Description For channel 1 (:CALC1) to channel 4 (:CALC4) (specified with the
:CALC{1-4}:PAR{1-4}:SEL command), sets the ripple limit band for ripple value display.
Parameters
Query response {numeric}<newline><^END>
Example of use
10 OUTPUT 717;":CALC1:RLIM:DISP:SEL 5"
20 OUTPUT 717;":CALC1:RLIM:DISP:SEL?"
30 ENTER 717;A
Related commands :CALC{1-4}:PAR{1-4}:SEL on page 286
:CALC{1-4}:RLIM on page 286
:CALC{1-4}:RLIM:DISP:LINE on page 288
:CALC{1-4}:RLIM:DISP:VAL on page 290
Equivalent key
[Analysis] - Ripple Limit - Ripple Band
<numeric>
Description The ripple limit band.
Range 1 to 12
Preset value 1
Page view 288