410 Appendix B
Key Definitions
Softkeys displayed by pressing the [System] key
MIDDLE VALUE Sets the limit center value of the measured value at the sweep start point of the
segment
1
. When setting the center value, also set the difference value (difference
between upper and the lower limits) with the DELTA LIMIT key. This kind of
limit configuration set by the center value and the difference value can be used as
an alternative to a limit configuration set by the upper and lower limits.
LIMVSTAR <value>
DELTA LIMIT Sets the limit difference value of the measured value at the sweep start point of
the segment
1
. When setting the difference value, also set the center value with
the MIDDLE VALUE key. This kind of limit configuration set by the center
value and the difference value can be used as an alternative to a limit
configuration set by the upper and lower limits.
LIMDSTAR <value>
more 1/3 Displays Table B-85, “Segment edit (Edit Limit) menu (2/3),” on page 410. (N/A)
done Finishes the editing of the segment, replaces the segment before the editing with
the new segment, and stores it. Also, returns to Table B-83, “Limit line edit (Edit
Limit) menu,” on page 409.
LIMSDON
cancel Cancels the editing of the segment and returns to Table B-83, “Limit line edit
(Edit Limit) menu,” on page 409. The segment before the editing remains
unchanged.
LIMSQUI
1. Even if you have set the limits with the MIDDLE VALUE (center value) key and the DELTA LIMIT (difference value) key, you
can convert the table into the upper and lower limit format by pressing the UPPER LIMIT key or the LOWER LIMIT key. On
the other hand, even if you have set the limits with the UPPER LIMIT (upper limit) key and the LOWER LIMIT (lower limit)
key, you can convert the table into the center and difference value format by pressing the MIDDLE VALUE key or the DELTA
LIMIT key.
Table B-85 Segment edit (Edit Limit) menu (2/3)
Key operation: [System] - LIMIT TEST - EDIT LIMIT LINE - EDIT - more 1/3
[System] - LIMIT TEST - EDIT LIMIT LINE - ADD - more 1/3
Softkey Function GPIB command
STOP Sets the sweep stop value of the segment. LIMSTOP <value>
UPPER LIMIT Sets the upper limit of the measured value at the sweep stop point of the
segment
1
. Be sure to set both the upper and lower limits. If an upper limit is not
required, set an extremely large value (for example, 1G) as the upper limit. If you
set the upper limit smaller than the lower limit, both limits are set to the newly
entered value automatically.
LIMUSTOP <value>
LOWER LIMIT Sets the lower limit of the measured value at the sweep stop point of the
segment
1
. Be sure to set both the upper and lower limits. If a lower limit is not
required, set an extremely small value (for example, -1G) as the lower limit. If
you set the lower limit greater than the upper limit, both limits are set to the
newly entered value automatically.
LIMLSTOP <value>
MIDDLE VALUE Sets the limit center value of the measured value at the sweep stop point of the
segment
1
. When setting the center value, also set the difference value (difference
between the upper and lower limits) with the DELTA LIMIT key. This kind of
limit configuration set by the center value and the difference value can be used as
an alternative to the limit configuration set by the upper and lower limits.
LIMVSTOP <value>
Table B-84 Segment edit (Edit Limit) menu (1/3)
Key operation: [System] - LIMIT TEST - EDIT LIMIT LINE - EDIT
[System] - LIMIT TEST - EDIT LIMIT LINE - ADD
Softkey Function GPIB command