Chapter 7 507
Language Reference
MKA Marker Amplitude
MKA Marker Amplitude
Syntax
Figure 7-154 MKA Syntax
Description
The MKA command returns the amplitude of the active marker. If no
marker is active, MKA places a marker at the center of the trace and
returns that amplitude value.
Query Response
Figure 7-155 MKA Query Response
Example
10 OUTPUT 718;"IP;SNGLS;"
20 INPUT "ENTER IN DESIRED CENTER FREQUENCY, IN MHZ",Cf
30 INPUT "ENTER IN DESIRED FREQUENCY SPAN, IN MHZ",Sp
40 OUTPUT 718;"CF ";Cf;"MHZ;"
50 OUTPUT 718;"SP ";Sp;"MHZ;"
60 OUTPUT 718;"TS;MKPK HI;"
70 OUTPUT 718;"MKA?;AUNITS?;"
80 ENTER 718 USING "K";Mka,Aunits$
90 PRINT "HIGHEST PEAK IS",Mka,Aunits$
100 END