Agilent Technologies N8201A Service Manual Page 170

  • Download
  • Add to my manuals
  • Print
  • Page
    / 332
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 169
170 Agilent N8211A/N8212A Performance Upconverter Synthetic Instrument Module, 250 kHz to 20 / 40 GHz
7 System Commands
Calibration Subsystem (:CALibration)
:DCFM
Supported All with Option UNT
:CALibration:DCFM
Initiates a DCFM or DCΦM calibration depending on the currently active modulation. This
calibration eliminates any dc or modulation offset of the carrier signal.
Use this calibration for externally applied signals. While the calibration can also be
performed for internally generated signals, dc offset is not a normal characteristic for them.
If the calibration is performed with a dc signal applied, any deviation provided by the dc
signal will be removed and the new zero reference point will be at the applied dc level. The
calibration will have to be performed again when the dc signal is removed in order to reset
the carrier signal to the correct zero reference.
:IQ
Supported N8212A
:CALibration:IQ
Initiates an I/Q calibration for a range of frequencies. For setting range frequencies, refer
to“:IQ:STARt" on page 171, and “:IQ:STOP" on page 172.
:IQ:DC
Supported N8212A
:CALibration:IQ:DC
Starts and performs a one– to two–second adjustment that is not traceable to a standard.
However, it will minimize errors associated with N8212A internal voltage offsets. This
adjustment minimizes errors for the current N8212A setting and at a single frequency. The
DC adjustment is volatile and must be repeated with each N8212A setting change. This
command can be sent while the RF On/Off is set to Off and the adjustment will still be valid
when the RF is enabled.
The I/Q DC adjustment is dependent upon a number of instrument settings. If any of the
instrument settings change, the adjustment will become invalid. The dependent instrument
settings are:
RF frequency
I/Q attenuation level
I/Q polarity settings
Page view 169