Using the LAN Interface 2
Agilent N8211A/N8212A Performance Upconverter Synthetic Instrument Module, 250 kHz to 20 / 40 GHz 45
How to Troubleshoot Connectivity Problems on the Network
The Synthetic Instrument Finder program is used to find instruments on a network when
the N8211A/N8212A is connected through a company LAN router or cross-over cable.
There are three possible configurations:
• connecting the PC through a company wide site LAN connection to the
N8211A/N8212A
• connecting the PC to the same private LAN network as the instrument
• connecting the PC directly to the instrument using a cross-over cable - this would
typically be used for troubleshooting and is not normally used to control an instrument
directly
How to Determine a PCs Configuration Settings
From a DOS Window
1 From the Windows Desktop, click Start > Run.
2 At the Open: prompt, type CMD and press Enter to open a DOS window.
3 At the command prompt, type ipconfig/all to display the PCs network connection
details.
Or,
From the PCs Control Panel
1 From the Windows Desktop, click Start > Settings > Control Panel > Network and
Internet Connections.
2 From the Network and Internet Connections window, double-click the Local Area
Connection.
3 In the Local Area Connection Status dialog, click the Support tab and click Details to
display the PCs Network Connection Details.
The Network Connection Details include:
• Physical Address
• DHCP status, enabled or disabled (displayed when using the DOS window ipconfig
command only)
• Auto configuration enabled or disabled (displayed when using the DOS window ipconfig
command only)
• IP Address
• Subnet Mask
• Default Gateway
• DHCP Server Address